19
2.10 System Power Up
With power applied to the backplane, the McIAS 1610 red major alarm LED should
be lit.
Note:
Prior to turning on the McIAS 1610 power switch, make certain that a terminal
is connected and power to it is turned on.
McIAS 1610 will take approximately 2 minutes to initialize.
1. Turn on system power to the McIAS 1610 using the switch located on the
power supply board. The red major alarm LED is lit and will remain lit until the
system has finished initializing. The green power LED should remain lit
continually.
2. When the power switch is turned on, all of the LEDs on the SBC will come on
briefly. As the system initializes, LEDs on the SBC will either flicker or remain on
steadily. A series of self tests and processes being started up will be displayed
on the terminal during initialization.
3. When the system has completed initialization, the installer should see the
following:
!
McTi board LEDs:
McTi-30: All LEDs are off
McTi-24: Green LED is on
McTi-8L: Activity flashes
!
Red major alarm LED is off (if this LED is still lit, see Note below)
!
"Login" prompt appears on the terminal
!
SBC LEDs: See Section 1.3.1
!
Power LED is lit brightly
!
All other LEDs are off
Note:
If the red major alarm LED is still lit at the end of initialization, this could be
caused by more than 50% of the trunks not connected to the CO.
4. If there appears to have been a problem with system initialization, push the
RESET switch on the front of the SBC board.
5. Display the Error Log (McIAS 1610/IP) or Alarm Log (McIAS 1610/68) to see if
any errors occurred during system initialization. Refer to the applicable document
for more information:
McIAS 16xx/IP System Operation Manual (P/N 41318310), Section 3.4
McIAS 16xx/68 EASM Operator's Guide (P/N 51315820), Section 2.4.2.1
6. Correct errors, if any.
Содержание McIAS 1610 Series