User Guide
Tuning for Customer Motor
DRM028 — Rev 0
Designer Reference Manual
MOTOROLA
User Guide
155
9. Set PC master software control mode and start motor (see
Application Control
and
PC Master Software (Remote)
Operating Mode
)
10. Set the speed to the middle of minimal and maximal speed
11. Increase, step by step, the proportional gain
SPEED_PIREG_P_GAIN with PC master software, until speed
noise or oscillation appears, or up to 128
12. If SPEED_PIREG_P_GAIN is set to 128, increase proportional
gains in SPEED_PIREG_P_GAINSCALELEFT further with PC
master software, steps 0, 1, 2 ... 8 otherwise leave
SPEED_PIREG_P_GAINSCALELEFT as 0
13. Increase, step by step, the integral gain SPEED_PIREG_I_GAIN
with PC master software, up to current oscillation or noise, or up
to 128
14. If SPEED_PIREG_I_GAIN is set to 128, do further integral gain
increases to SPEED_PIREG_I_GAINSCALELEFT with PC
master software, steps 6, 5, 4...0; otherwise, leave
SPEED_PIREG_I_GAINSCALELEFT as 7
15. You can further evaluate the setting of the regulator parameters in
order to get a smoother current waveform until the regulation
seems to be performing well
16. Open
const_cust_x.h
and modify the regulator parameters with
the final variable values evaluated with PC master software
17. Start motor (see
Application Control
and
PC Master Software
(Remote) Operating Mode
)
18. Set minimal desired speed
19. If the displayed real speed is not able to go down to the desired
minimal speed, it is necessary to decrease minimal PWM duty
cycle DUTY_PWM_MIN in
const_cust_x.h
!
20. Then, you can tune dynamic characteristics of speed regulators
(steps
22.
to
29.
) or finish tuning the regulators
21. Start motor (see
Application Control
and
PC Master Software
(Remote) Operating Mode
)
F