User Guide
Tuning for Customer Motor
DRM028 — Rev 0
Designer Reference Manual
MOTOROLA
User Guide
153
Range: <0,255>
where the current regulator integral gain is:
(EQ 6-13.)
These constants can be calculated according to regulators theory. The
speed sampling (regulator execution) period is
PER_T3_RUN_US
=
2.560 ms at default software setting. Another recommended solution is
experimental setting.
NOTE:
SPEED_PIREG_P_GAINSCALELEFT, SPEED_PIREG_P_GAIN,
SPEED_PIREG_I_GAINSCALERIGHT, SPEED_PIREG_I_GAIN can
be evaluated with PC master software tuning file tuning_bldc.pmp.
We suggest using PC master software with tuning file tuning_bldc.pmp
for regulator parameters evaluation. You can use this procedure:
1. Ensure that the start-up and commutation parameters were set
properly (
Start-up Constants and Maximal Commutation
Period
)
6.5.4.3
in
const_cust_x.h
2. Set
const_cust_x.h
:
SPEED_PIREG_P_GAINSCALELEFT
0
SPEED_PIREG_P_GAIN 0
SPEED_PIREG_I_GAINSCALERIGHT 7
SPEED_PIREG_I_GAIN 0
3. Ensure that
COMMUT_REV
,
SPEED_RANGE_MAX_RPM
,
SPEED_MAX_RPM
are set properly in
const_cust_x.h
4. Set
SPEED_MIN_RPM
as required (should be
SPEED_MIN_RPM
>
SPEED_MAX_RPM/5
for reliable
commutation at low speed)
KI
SPEED_PIREG_I_GAIN*2
SPEED_PIREG_I_GAINSCALERIGHT
–
(
)
=
F
re
e
sc
a
le
S
e
m
ic
o
n
d
u
c
to
r,
I
Freescale Semiconductor, Inc.
For More Information On This Product,
Go to: www.freescale.com
n
c
.
..