MOTOROLA
M68000 8-/16-/32-BIT MICROPROCESSORS USER’S MANUAL
6- 17
protect memory contents from erroneous accesses. Only an external reset operation can
restart a halted processor.
LOW
HIGH
LOWER ADDRESS
R/W
ACCESS ADDRESS
INSTRUCTION REGISTER
STATUS REGISTER
5
4
3
2
1
0
15
14
13
12
11
10
9
8
7
6
FUNCTION CODE
I/N
PROGRAM COUNTER
LOW
HIGH
R/W (Read/Write): Write=0, Read=1. I/N (Instruction/Not): Instruction=0, Not=1
Figure 6-7. Supervisor Stack Order for Bus or Address Error Exception
6.3.9.2 BUS ERROR (MC68010). Exception processing for a bus error follows a slightly
different sequence than the sequence for group 1 and 2 exceptions. In addition to the four
steps executed during exception processing for all other exceptions, 22 words of
additional information are placed on the stack. This additional information describes the
internal state of the processor at the time of the bus error and is reloaded by the RTE
instruction to continue the instruction that caused the error. Figure 6-8 shows the order of
the stacked information.