31
MN003563A01-B
Operation and Configuration
NOTE
The range of band 28, according to 3GPP standard is 45 Mhz. The LXN 500 supports a partial
range of 25 Mhz of the full range.
4.
Enter the
DL
(Downlink) central frequency MHz (in 0.1 MHz precision) or
DL EARFCN
and click the
Calculate
button to automatically populate all center frequency fields.
5.
Click the
Set band info
button to save changes or
Get band Info
to populate the field with the last
saved values.
6.
In the
Antenna
section of the
eNodeB
tab, set identical
Tx power
(Transmit power in mW) to
LTE1
and
LTE2
antenna ports (See
).
NOTE
Tx power range can be set from 1 to 1000 mW RMS (0 to 30 dBm).
7.
Click the
Set antenna info
button to save changes
Get antenna Info
to populate the field with the
last saved values.
8.
In the
Physical Cell ID
field, enter the Physical Cell ID of the LXN 500 (Range
0-503
) and click the
Set
to save changes or
Get
to restore the last saved value.
CAUTION
Physical Cell ID is generally unique number used to identify each base transceiver station
(BTS) within a LTE network. When using more than one LXN 500 in a LTE network, DO NOT
set identical Physical Cell ID to two LXN 500s or any linked base station that may have
overlapping radio coverage area.
9.
In the
Logical Cell ID
field. Enter the Logical Cell ID and click the
Set
to save changes or
Get
to
restore the last saved value.
Setting the System
The System tab is used by administrators and technicians to diagnose, troubleshoot and show status of
the LXN 500 hardware and software.
PLMN Settings
A public land mobile network (PLMN) is a network that is established and operated by an administration
for the specific purpose of providing land mobile telecommunications services to the public.
A PLMN is identified by the Mobile Country Code (MCC) and the Mobile Network Code (MNC). Each
operator providing mobile services has its own PLMN. When the LXN 500 is interconnect other
networks, the PLMN interconnect with other PLMNs to create links between providers.
Perform this procedure to set the PLMN of the LXN 500:
Procedure:
1.
Sign in to the LXN 500 O&M Configuration site (See
).
2.
Click the
System
tab.
3.
Click
PLMN
.
Result:
The
PLMN Settings
screen is displayed.
4.
In the
MCC
field, enter the MCC number
5.
In the
MNC
field, enter MNC number
6.
Click the
Set
button to save changes or
Get
to populate the field with the last saved values.
Result:
After setting a new PLMN value and clicking
Set
, the eNodeB restarts. This procedure takes
Содержание LXN 500
Страница 10: ...MN003563A01 B About LXN 500 10 Send Feedback ...
Страница 16: ...MN003563A01 B Overview 16 Send Feedback ...
Страница 46: ...MN003563A01 B Operation and Configuration 46 Send Feedback ...
Страница 58: ...MN003563A01 B Vehicle Installation 58 Send Feedback ...
Страница 64: ...MN003563A01 B Troubleshooting and Maintenance 64 Send Feedback ...