Canopy
T1/E1
Multiplexer
September
2004
T1/E1
Multiplexer
FPGA
Version
3.4
Page
45 of 73
Action Steps
Set timing mode
NOTE:
Timing mode applies to all four E1 lines. Loopback mode loops the T1/E1
Tx clock to the T1/E1 Rx. Recovered mode recovers the T1/E1 clock from the
incoming T1/E1 over Ethernet bit stream (recovers the clock from the far end
T1/E1). The default timing mode is Recovered.
For master clock timing mode, enter
set clock source loopback
RESULT:
The system responds
Clock source is loopback
For slave clock timing mode, enter
set clock source recovered
RESULT:
The system responds
Clock source is recovered
Log off
Enter
lo
.
RESULT:
The system responds
goodbye
.
end of procedure
2.5
CONFIGURATION
PROCEDURES
USING
THE
EMS
2.5.1
Logging
into
the
System
Procedure 14: Logging in using the EMS
If you are using the EMS to access the system, follow the steps below to log in:
1. Select the proper
COM Port
for your PC.
NOTE:
COM1 through COM4 are supported.
2. Enter
the
User Name
.
NOTE:
The default username is
admin
. This value cannot be changed.
3. Enter
the
Password
.
NOTE:
The default password is
123
. If the password has been changed, enter
the correct password.
4. Select
the
Login
button to continue with the login.
NOTE:
If the login is unsuccessful, the system will generate a pop-up error
window. You may return to the Login window to correct the data.
Issue
3