SPECIFICATIONS

Display: 

3¾ digit, 2400 counts (auto-range mode), 2500

counts (manual-range mode).

Polarity: 

Automatic, positive implied, negative polarity

indication.

Overrange

: "OL"or "-OL" is displayed.

Low battery indication: 

The " " is displayed when the

battery voltage drops below the operating level.

Measurement rate: 

2.5 times per second, nominal.

Operating Environment: 

0°C to 40°C at < 70% relative

humidity.

Storage Temperature: 

-20°C to 60°C, 0 to 80% R.H.

with battery removed from meter.

Accuracy: 

Stated accuracy at 23°C ± 5°C, <75% relative

humidity.

Safety:

 According to EN61010-1 protection class III

overvoltage category (CAT III 600V) pollution degree

2.

For Indoor use only

Altitude:

 UP to 2000m.

Auto Power off: 

30 minutes after last rotary switch or push

button operation. Turn the meter off then on to resume

operation.

Power: 

single standard 9-volt battery, NEDA 1604, JIS

006P, IEC 6F22.

Battery life: 

200 hours typical with carbon-zinc.

Dimensions: 

192mm (H) x 91mm (W) x 52.5mm (D).

Weight: 

397g including battery.

Accessories: 

One pair test leads, One spare fuse installed,

9V battery (installed) and Operating Instructions.

SAFETY INFORMATION

For measurements on Energised circuits Robin Elec-

tronics recommends the use of Fused test leads complying

with the requirements of Standard GS38, to maximise user

safety. Please contact Robin Electronics for further infor-

mation.

The following safety information must be observed to

ensure maximum personal safety during the operation of

this meter:

1. Do not use the meter if the meter or test leads look

damaged, or if you suspect that the meter is not operating

properly.

2. Do not use this instrument outside the specifications

quoted.

3. Turn off power to the circuit under test before cutting,

unsoldering, or breaking the circuit. Small amounts of

current can be dangerous.

4. Use caution when working above 60V dc or 30V ac rms.

Such voltages pose a shock hazard.

5. When Using the probes, keep your fingers behind the

finger guards on the probes.

6. Measuring voltage which exceeds the limits of the

multimeter may damage the meter and expose the

operator to a shock hazard. Always respect the meter

voltage limits as stated on the front of the meter.

7. If the meter is used in a manner not specified by the

manufacturer, the protection provided the meter may be

impaired.

8. Refer all servicing and repairs to Robin Electronics.

OPERATING INSTRUCTIONS

MODEL AR6004

DIGITAL MULTIMETER

DC VOLTS

Ranges:

 250mV,2.5V,25V,250V,600V

Resolution: 

100µV

Accuracy:

±(0.25%rdg + 5dgts) on 250mV

 

range

±(0.25%rdg + 1dgt) on other ranges

Input impedance: 

>10M

Overload 

&

&

&

&

&

 protection:

 600VDC or AC rms

AC VOLTS

 

(50Hz - 500Hz)

Ranges: 

250mV,2.5V,25V,250V,600V

Resolution:

 1mV(100µA on 250mV range)

Accuracy: 

±(0.75% of 4dgts) on 2.5V to 600V

                 no specification on 250mV range

Input impedance: 

10M

Overload 

&

&

&

&

&

 protection: 

600VDC or AC rms

RESISTANCE

Ranges:

 250

,2.5K

,25K

,250K

,2500K

,25M

Resolution:

 100m

Accuracy:

±(0.3%rdg + 3dgts) on 250

Ω 

range

±(0.3%rdg + 1dgt) on 2.5K

Ω 

to 2500K

ranges

±(3.5%rdg + 4dgts) on 25M

Ω 

range

Open circuit volts: 

0.4Vdc

Overload protection: 

500VDC or AC rms

CONTINUITY

Audible indication: 

<100

Overload protection: 

500VDC or AC rms

DIODE TEST

Accuracy: 

±(3.0%rdg + 3dgts)

Resolution: 

1mV

Test current:

 0.5±0.3mA

Test voltage:

 <1.6V