Canopy
T1/E1
Multiplexer
September
2004
T1/E1
Multiplexer
FPGA
Version
3.4
Page
39 of 73
2.4.5
Configure
Ports
Procedure 10: Configuring the Ethernet ports using the CLI
Perform this procedure to configure the Ethernet ports using the CLI manager.
NOTE:
Both Ethernet ports operate at 100 Mbps Full Duplex. They will not operate at
10 Mbps or at half duplex.
Action Steps
Log in
Press Enter.
At the
username
prompt, enter
admin
.
At the password prompt, enter
password
.
Set BH-side Ethernet auto-
negotiation
Enter
set canopy port auto negotiation [on/off]
where
on
enables auto negotiation at 100 Mbps Full Duplex (as default).
off
forces the port to 100 Mbps Full Duplex without auto negotiation.
RESULT:
The system responds
Canopy port auto-negotiation is: on
Set LAN-side Ethernet
auto-negotiation
Enter
set lan port auto negotiation [on/off]
where
on
enables auto negotiation at 100 Mbps Full Duplex (as default).
off
forces the port to 100 Mbps Full Duplex without auto negotiation.
RESULT:
The system responds
LAN port auto-negotiation is: on
Log off
Enter
lo
.
RESULT:
The system responds
goodbye
.
end of procedure
Issue
3