background image

4A

4B

F1

F2

F3

L1 L2

V+

L3

T1

LAMP

T2 T3

LS

LO

OL

CL LE

LA

ST PU

LS

LO ST PU OL

LS LE

LA

R G B Y V+

EN

EN

• Power Supply

400V 3~ ±10% (50Hz-60hz)

• Flashing light’s output (NO)

230Vac (1000W máx)

• RGB Lightbulb’s output

24Vdc (100mA máx)

• Motor’s output

400Vac (1500W máx)

• Auxiliary accessories output

24Vdc (325mA máx)

• Working temperature

-25°C a +55°C

• Incorporated Radio Receptor

433,92 Mhz

• OP Transmitters

12bits or Rolling Code

• Maximum Memory Capacity

100 (full opening)

 100 (pedestrian opening)

• Control board Dimensions

172 x 184 mm

• Fuse F1-F2-F3

T 8A 250V

• Fuse F4

T 63ma 250V retardo

02. CONTROL BOARD

TECHNICAL SPECIFICATIONS

The 

MC410

 is a three-phase electronic control board (400V 3 phases) with a soft start and 

stop system, developed mainly to equip the engines STARK (sliding gates) and KVM115 

(sectional gates) of the Motorline brand.

The soft start and stop functions enable more precise operation, thus saving all mechanical 

components of the gate and operator, as well as protection against exponential current 

increase when starting AC motors.

Soft stopping also reduces the likelihood that the doors will be blocked when closing, as well 

as reducing noise when closing the door.

02. CONTROL BOARD

CONNECTORS

CN1

01 (L1)

 • Input Phase 1 - 400V

02 (L2)

 • Input Phase 2 - 400V

03 (L3)

 • Input Phase 3 - 400V

Power Supply 400Vac

04 (Ground)

 • Grounding connection

05 (Ground)

 • Grounding connection

Motor and power ground connection

06 (T1)

 • Motor Output Phase 1 - 1500W máx.

07 (T2)

 • Motor Output Phase 2 - 1500W máx.

08 (T3)

 • Motor Output Phase 3 - 1500W máx.

Power Supply 110/230Vac

09 (LAMP1)

 • Flashing light Output - 1000W

10 (LAMP2)

 • Flashing light Output - 1000W

Courtesy light or Flashing light: 

This output

allows the connection of a courtesy light or a

Flashing light.

CN2

11 (V+)

 • Power supply 24Vdc 325mA max.

12 (GND)

 • Power supply 24Vdc 325mA max.

24Vdc Auxiliary Power Supply

13 (LS)

 • Full Pulsing Input (NA)

14 (GND)

 • Common

15 (LO)

 • Pedestrian Pulsing Input (NA)

Pushbuttons: 

This circuit allows the connection

of pushbuttons for full or pedestrian opening

16 (ST)

 • Button STOP Input (NC)

17 (PU) 

• Sequential Pushbutton (NA)

ST: 

This circuit allows the connection of a button

stop. Its operation depending on the

P6 configuration (check page 9A).

18 (OL)

 • Opening limit-switch (NC)

19 (GND)

 • Common

20 (CL)

 • Closing limit-switch (NC)

Limit switches: 03 and 04: 

The control unit requires 

the connection of limit switches when opening 

and closing (both in NC). The activation of any of 

the limit switches causes the movement to stop 

immediately. The activation of the limit switches is 

visible on the display by OP (opening limit switch 

activated) and CL (closing limit switch activated), 

as well as on the OL and CL leds.

21 (LE)

 • Photocells  1 (NC)

22 (GND)

 • Common

23 (CL)

 • Photocells  2 (NC)

Safety circuits: 

This circuit allows the connection 

of photocells. Its operation depending

on the configuration of the P5 and P6 menus

(check page 9A).

24 (GND)

 • Common

25 (ANT)

 • Antenna

LEDs

LED

s

+24V

 • LED On indicates that the line for V+ output is OK. 

+5V

 • LED On indicates that the line for 5V is OK.

LS

 • LED On when the Pedestrian Pushbutton is pressed.

LO

 • LED On when the Total Pushbutton is pressed.

ST

 • LED On when the ST circuit is closed.

PU

 • LED On when the Sequential Pushbutton is pressed.

OL

 • LED On indicates limit switch opening in closed state. That is, it is not within limits.

CL

 • LED On indicates limit switch Closing in closed state. In other words, it is not within the 

limits.

LE

 • LED On when the 

↓ LE

 circuit is closed.

LA

 • LED On when the 

↓ LA

 circuit is closed.

Содержание MC410

Страница 1: ...F 1 F 2 F 3 L1 L2 V L3 T1 LAMP T2 T3 LS LO OL CL LE LA ST PU LS LO ST PU OL LS LE LA R G B Y V v1 2 REV 03 2021 MC410 MC410 EN INSTALLER AND USER S MANUAL...

Страница 2: ...cable in countries with recycling systems This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should n...

Страница 3: ...with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorize...

Страница 4: ...esanyrepairormodification unlocktheautomatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the ma...

Страница 5: ...light or Flashing light This output allows the connection of a courtesy light or a Flashing light CN2 11 V Power supply 24Vdc 325mA max 12 GND Power supply 24Vdc 325mA max 24Vdc Auxiliary Power Supply...

Страница 6: ...U R G B Y V TX RX TX RX R G B Y V F 2 F 3 L1 L2 L3 T1 LAMP T2 T3 V LS LO OL CL ST PU EN 03 INSTALLATION INSTALLATION MAP STARK Pedestrian or Close Pushbutton Motor connection Total or Open Pushbutton...

Страница 7: ...2 COM 3 4 NC NO TX RX 9 10 10 9 1 2 3 11 4 6 5 11 8 7 1 2 3 5 6 4 7 8 EN 03 INSTALLATION INSTALLATION MAP KVM105 KVM110 KVM115 Connections Motor Pushbutton Flashlight Example Control Board Loading do...

Страница 8: ...ion appears 05 Press the command button you want to program The display will blink and move to the next free location 03 Press cmd once to confirm 01 Press the cmd button for 3 sec PROGRAMMING TRANSMI...

Страница 9: ...ST emergency button 00 01 Operating logic Automatic mode function 00 01 Step by step mode function Condominium mode function Flashing light Flashing opening and closing 00 00 Step by step mode functio...

Страница 10: ...1 second 04 When programming is complete the display returns to the initial state This menu allows you to program the engine s working time in a semi automatic way allowing you to manually define the...

Страница 11: ...disable photocells Define whether this security will act when opening or closing the gate 00 acts on closing 01 acts on opening Define the behavior that the gate will have when this security is activ...

Страница 12: ...hing light will flash the 1st free position appears in the display Each time you store 1 command the control board will exit remote programming If you want to memorize more commands you will always ha...

Страница 13: ...eters 03 Press MENU to edit the value 04 Use UP and DW to change the value 05 Press MENU for 2sec to save the new value DECELERATION SPEED This menu allows you to adjust the deceleration speed DEFAULT...

Страница 14: ...otor is in star configuration and that it is a 400V motor that does not exceed 1500W INDICA ES DO DISPLAY 05 FUNCTIONS IN STOP POSITION FULLY OPEN IN STOP POSITION MIDDLE POSITION IN STOP POSITION FUL...

Страница 15: ...in order to find out if it has problems see page 11B 3 f the motors work the problem is from control board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motors don...

Отзывы: