4A
4B
F1
F2
F3
L1 L2
V+
L3
T1
LAMP
T2 T3
LS
LO
OL
CL LE
LA
ST PU
LS
LO ST PU OL
LS LE
LA
R G B Y V+
EN
EN
• Power Supply
400V 3~ ±10% (50Hz-60hz)
• Flashing light’s output (NO)
230Vac (1000W máx)
• RGB Lightbulb’s output
24Vdc (100mA máx)
• Motor’s output
400Vac (1500W máx)
• Auxiliary accessories output
24Vdc (325mA máx)
• Working temperature
-25°C a +55°C
• Incorporated Radio Receptor
433,92 Mhz
• OP Transmitters
12bits or Rolling Code
• Maximum Memory Capacity
100 (full opening)
100 (pedestrian opening)
• Control board Dimensions
172 x 184 mm
• Fuse F1-F2-F3
T 8A 250V
• Fuse F4
T 63ma 250V retardo
02. CONTROL BOARD
TECHNICAL SPECIFICATIONS
The
MC410
is a three-phase electronic control board (400V 3 phases) with a soft start and
stop system, developed mainly to equip the engines STARK (sliding gates) and KVM115
(sectional gates) of the Motorline brand.
The soft start and stop functions enable more precise operation, thus saving all mechanical
components of the gate and operator, as well as protection against exponential current
increase when starting AC motors.
Soft stopping also reduces the likelihood that the doors will be blocked when closing, as well
as reducing noise when closing the door.
02. CONTROL BOARD
CONNECTORS
CN1
01 (L1)
• Input Phase 1 - 400V
02 (L2)
• Input Phase 2 - 400V
03 (L3)
• Input Phase 3 - 400V
Power Supply 400Vac
04 (Ground)
• Grounding connection
05 (Ground)
• Grounding connection
Motor and power ground connection
06 (T1)
• Motor Output Phase 1 - 1500W máx.
07 (T2)
• Motor Output Phase 2 - 1500W máx.
08 (T3)
• Motor Output Phase 3 - 1500W máx.
Power Supply 110/230Vac
09 (LAMP1)
• Flashing light Output - 1000W
10 (LAMP2)
• Flashing light Output - 1000W
Courtesy light or Flashing light:
This output
allows the connection of a courtesy light or a
Flashing light.
CN2
11 (V+)
• Power supply 24Vdc 325mA max.
12 (GND)
• Power supply 24Vdc 325mA max.
24Vdc Auxiliary Power Supply
13 (LS)
• Full Pulsing Input (NA)
14 (GND)
• Common
15 (LO)
• Pedestrian Pulsing Input (NA)
Pushbuttons:
This circuit allows the connection
of pushbuttons for full or pedestrian opening
16 (ST)
• Button STOP Input (NC)
17 (PU)
• Sequential Pushbutton (NA)
ST:
This circuit allows the connection of a button
stop. Its operation depending on the
P6 configuration (check page 9A).
18 (OL)
• Opening limit-switch (NC)
19 (GND)
• Common
20 (CL)
• Closing limit-switch (NC)
Limit switches: 03 and 04:
The control unit requires
the connection of limit switches when opening
and closing (both in NC). The activation of any of
the limit switches causes the movement to stop
immediately. The activation of the limit switches is
visible on the display by OP (opening limit switch
activated) and CL (closing limit switch activated),
as well as on the OL and CL leds.
21 (LE)
• Photocells 1 (NC)
22 (GND)
• Common
23 (CL)
• Photocells 2 (NC)
Safety circuits:
This circuit allows the connection
of photocells. Its operation depending
on the configuration of the P5 and P6 menus
(check page 9A).
24 (GND)
• Common
25 (ANT)
• Antenna
LEDs
LED
s
+24V
• LED On indicates that the line for V+ output is OK.
+5V
• LED On indicates that the line for 5V is OK.
LS
• LED On when the Pedestrian Pushbutton is pressed.
LO
• LED On when the Total Pushbutton is pressed.
ST
• LED On when the ST circuit is closed.
PU
• LED On when the Sequential Pushbutton is pressed.
OL
• LED On indicates limit switch opening in closed state. That is, it is not within limits.
CL
• LED On indicates limit switch Closing in closed state. In other words, it is not within the
limits.
LE
• LED On when the
↓ LE
circuit is closed.
LA
• LED On when the
↓ LA
circuit is closed.