16A
16B
LS LO FO FC
LA LE
FO
LO
LS
FC
1 2 3 4 5
EN
LE
LA
+V
1 2 3 4 5
R
Y
24V
G
B
1 2 3 4 5
24V
1 2
F
FE
N
P
N
AB COM
1 2 3 4 5 6 7 8 9
230v
COM
15A
15B
EN
EN
In the position corresponding to each transmitter input in low voltage, the control board has
a LED to identify the condition of it. The LED on indicates that the input is closed, while the
LED off indicates that the input is open.
TEST SCHEME
INPUTS TEST
07. COMPONENTS TEST
07. COMPONENTS TEST
All tests must be performed by skilled technicians due to serious danger
associated with the misuse of electrical systems!
For your safety, do not change the connections without it being disconnected
from the electric current.
01
• Remove the 3 wires from the motor in the
control board.
02
• Connect the motor wires to a terminal.
Add a plug to the terminal, taking into account
that the wires order indicated in the image
must be respected.
Phase
Motor cable
Motor cable
To detect which components have problems during a sectional door installation,
sometimes it's necessary to conduct tests with a direct connection to a 230V power
supply.
In the below diagram is shown how this connection must be made and how to merge the
different component wires.
NOTES:
• To perform the tests you don't need to remove the automatism from it's place, because
this way you can understand if the automatism, directly connected to the power, can
function correctly.
• The common wire of the motor must always be connected to the power supply;
• To reverse the automatism functioning direction, switch the Black wire with the Brown
wire of the automatism.