5A
5B
4A
4B
EN
EN
01
• Make the connections of all the accessories according to the connection scheme
(page 17).
02
• Connect the control board to a 230V power supply (3 and 4 - CN1 terminals).
03
• Make sure that the gate movement is the same as the one shown on the display:
04
• Check is the limit switches, so that the FC LED turns off during the closure and the
LED FO turns off during the opening.
05
• Make an automatic programming -
P0
menu (
page 6A
).
06
• If necessary, adjust the gate of the deceleration time in opening and closing -
P1
menu (
page 6B
).
07
• Adjust the strength and sensitivity of the motor -
P2
menu (
page 7A
).
08
• Make an automatic programming of the course again -
P0
menu (
page 6A
).
09
• Enable or disable the use of photocells in the
P5
menu (
page 8A
).
10
• Enable or disable the use of safety band in the
P6
menu (
página 8B
).
11
• Program a transmitter (
page 4B
).
The control board is now fully configured!
Check the menus from the programming pages in case you wish to configure other
features of the plant.
The installation process assumes that the gate has already limit switches
plates installed. For more information consult the motor's manual.
CLOSING
OPENING
If the display does not match the gate's
movement, turn off the control board from
the power supply e swap the 5 and 7 wires
from CN1 and check if it is correct with 3
and 4 from CN2.
ESSENTIAL STEPS FOR INSTALLATION
03. INSTALLATION
TRANSMITTERS
03. INSTALLATION
05
• Press cmd for 3sec
and the location will be
empty.
The display will show
the following location
with memorized
transmitter.
02
• The display will show
dL
, confirming that all
transmitters have been
erased.
01
• Press the
cmd button for 10sec.
01
• Press the
cmd button for
3sec.
Transmitter programming for total opening.
02
• SU
appears.
03
• Press cmd
once to confirm.
04
• Use
↑↓
to select the
transmitter
location you want
to delete.
05
• Press the command
button you want to program.
The display will blink and
move to the next free
location.
01
• Press the
cmd button for
3sec.
02
• SU
appears.
• PROGRAMMING TRANSMITTERS
• ERASE ALL THE TRANSMITTERS
• ERASE TRANSMITTERS
• If you do not press any key for 10
sec. the control board will return to
standby.
• Whenever you save or delete a
transmitter, the display will show the
following location. You can add or
delete transmitters without having
to go back to point 01.
04
• The first free
position appears.
03
• Press cmd
once to confirm.
To program transmitters, you must
close the gate or turn the power
OFF and ON again.