14A
14B
1
2
EN
EN
06. TROUBLESHOOTING
FINAL CONSUMERS AND SPECIALIZED TECHNICIANS INSTRUCTIONS
Problems
Behavior
Procedure
The awning is not
secure properly on
the wall.
• The screws are
not suitable for
the wall structure.
• Check the installation measures.
• Check that the number of screws is sufficient
and that they are indicated in this manual.
The awning does
not remain level
after opening.
• Changes to
the awning
after several
maneuvers.
• Check the level of the wall brackets.
• Check the level of the square tube.
The top does not
close in full.
• Detuning the top
or limit switch.
• Tune the motor limit switches.
The awning does
not work and the
motor makes no
noise.
• The motor goes
into thermal
protection after
2 openings and 1
closing.
• Wait 20 minutes.
The awning does
not work and the
motor makes no
noise.
• Protection
problem.
• Check the motor connection.
• Check closing operation by connecting directly
to the power supply.
05. MAINTENANCE
WATER SEALING BETWEEN FRAMES
This method is only applied when there are two or
more awnings leaning against each other, in order to
prevent the passage of water between the frames of
each awning.
Isolation
rail is applied to the union joint.
Apply silicone in the area where the two frames union.
Fit the rail to the union joint of the frames and press
for a few seconds.
1