background image

4

Safety Instructions

3

Safety Instructions

Maintain adequate clearances of 20”–24” around air
openings into the combustion chamber, clearances from
combustible material, provisions for accessibility and for
combustion and ventilating air supply. Keep the Liberty
Plus area clear and free from combustible materials,
gasoline, and other flammable vapors and liquids. The
appliance is not to be used in locations where flammable
vapor or explosive dust is likely to exist.

Do not obstruct the flow of combustion and ventilation air.

Keep the ventilating openings of the cylinder enclosure 
free and clear from debris.

Clean the Liberty Plus with a water damp cloth, if necessary. 

A maximum of a 20 lb. LP-Gas cylinder shall be used. 

The LP-Gas cylinder must be provided with a shut-off valve
terminating in an LP-Gas supply cylinder valve outlet
specified for Connection No. 510 in the Standard for
Compressed Gas Cylinder Valve Outlet and Inlet
Connections, ANSI/CGA-V-1-1977.

The LP-Gas cylinder supply system must be arranged for
vapor withdrawal and the cylinder must include a collar to
protect the cylinder valve.

The LP-Gas cylinder used shall be constructed and marked
in accordance with the specifications for LP-Gas cylinders
of the U.S. Department of Transportation (DOT) or The
National Standard of Canada CAN/CSA-B339.

The Liberty Plus shall be used outdoors only in a well
ventilated space and shall not be used in a building, garage, 
or any other enclosed area.

The LP-Gas cylinder must be disconnected and removed
from the appliance, if the appliance is stored indoors.

LP-Gas cylinders must be stored outdoors in a well-
ventilated area out of reach of children.

Disconnected cylinders must have threaded valve plugs
tightly installed and must not be stored in a building, garage,
or any other enclosed area.

Note: 

Some or all of the following required safety
instructions for propane powered devices may
apply to your Liberty Plus. Allow trap to cool for 5
minutes before re-starting.

Warning:

Improper installation, adjustment,

alteration, service or maintenance can cause injury
or property damage. Read the installation, operating
and maintenance instructions thoroughly before
installing or servicing the Liberty Plus.

Caution:

The gas pressure regulator provided with this

appliance must be used. This regulator is set for an outlet
pressure of 11.0 in. Water Column. The minimum inlet gas
supply pressure is 11.0 in. Water Column from regulator.

This unit is not intended to be installed in or on recreational
vehicles and/or boats.

• 

The gas supply must be turned off at the LP-Gas supply
cylinder when this appliance is not in use.

The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223. 1-1998 for US and with the CAN1-B149 for Canada.

To test for a gas leak, place soapy water around the
connector, regulator, and gas hose assembly. If bubbles
appear, there is a gas leak.

Inspect the hose before each use of the unit. If it is evident there
is excessive abrasion or wear, or the hose is cut, it must be
replaced prior to the unit being put into operation. The
replacement hose shall be that specified by the manufacturer.

The Liberty Plus is equipped with an internal spark ignition device.
Failure to follow starting procedure will result in the trap not starting.

Installation and repair should be done by a qualified service
person (find service centers on www.mosquitomagnet.com).
The heater should be inspected before use and at least
annually by a qualified service person. More frequent
cleaning may be required as necessary. It is imperative that
the control compartment, burners, and circulating air
passageways of the heater be kept clean.

Children and adults should be alerted to
the hazards of high surface temperatures
and should stay away to avoid burns or
clothing ignition. 

Young children should be carefully
supervised when they are in the
area of the heater. Keep out of 
reach of children.

Clothing or other flammable materials
should not be hung from the heater, 
or placed on or near the heater.

The pressure regulator and hose assembly supplied with this
appliance must be used for connection to the LP-Gas
cylinder. Replacement pressure regulators and hose
assemblies must be specified by the manufacturer. 

Avoid improper use of extension cords. Keep connections
away from moisture and avoid damage to the cord.

If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid hazard.

Please contact Customer Care 

if you have any questions at: 

1-800-953-5737 

or visit www.mosquitomagnet.com

Please read and follow all safety
instructions and warnings.

Содержание Liberty Pluse

Страница 1: ...For Outdoor Use Only 1440 604 Rev E...

Страница 2: ...logy Woodstream Corporation 69 North Locust Street Lititz PA 17543 1 800 953 5737 www mosquitomagnet com Patents USA Nos 6 145 243 6 286 249 6 817 140 6 840 005 6 848 466 7 243 457 and 7 281 351 Canad...

Страница 3: ...egulatorprovidedwiththis appliance must be used This regulator is set for an outlet pressure of 11 0 in Water Column The minimum inlet gas supply pressure is 11 0 in Water Column from regulator This u...

Страница 4: ...arts Included Self Contained Liberty Plus Power Head 1 Trumpet 1 Support Pole 1 Base Support 1 Regulator Hose 1 Bug Bag Mosquito Magnet Octenol Biting Insect Attractant EPA Reg No 72563 1 Short Range...

Страница 5: ...front of you within 5 6 feet of ground cover i e bushes flowerbeds tree line marshbed Ensure that trap is not directlyagainstanyblockadessuchasbuildings fences etc 4 It is recommended that the trap b...

Страница 6: ...preferably by mouth to mouth if possible Call a poison control center or doctor for further treatment advice Have the product container or label with you when calling a poison control center or docto...

Страница 7: ...tank after a tank change be sure to fully tighten the regulator knob onto the tank No need to use tools but do turn the knob as far as possible by hand When this is done loosen the knob 1 4 turn then...

Страница 8: ...Possible Cause Problem Easy Quick Clear Valve Troubleshooting Important Extinguish all smoking materials prior to use of Easy Quick Clear Valve Do not stand directly behind the Quick Clear cartridge d...

Страница 9: ...e a defect Woodstream Corporation will issue a Return Goods Authorization RGA number The defective unit or parts must be returned for warranty inspection using the RGA number when applicable as identi...

Страница 10: ...Manual de operaci n...

Страница 11: ...ada Counterflow Technology Woodstream Corporation 69 North Locust Street Lititz PA 17543 1 800 953 5737 www mosquitomagnet com Patentes EE UU No 6 145 243 6 286 249 6 817 140 6 840 005 6 848 466 7 243...

Страница 12: ...eartefacto Estereguladorest fijado paraunapresi ndesalidade28cmdecolumnadeagua Lapresi nm nimadelsuministrodegasdeentradaes para28cmdecolumnadeaguadelregulador Esta unidad no est dise ada para instala...

Страница 13: ...cluidas Artefacto Liberty Plus aut nomo Cabezal de alimentaci n el ctrica 1 Trompeta 1 Poste de soporte 1 Soporte de la base 1 Manguera del regulador 1 Bolsa para insectos Cebo atrayente para insectos...

Страница 14: ...m es decir arbustos cantero de flores l neas de rboles pantano Aseg rese que la trampa no est ubicada contra objetos de bloqueo como edificios cercas etc 4 Se recomienda ubicar la trampa en la sombra...

Страница 15: ...n Lleve a la persona al aire fresco Si la persona no est respirando llame al 911 o a una ambulancia luego aplique respiraci n artificial preferiblemente boca a boca si es posible Llame al centro de c...

Страница 16: ...justar completamente la perilla del regulador al tanque No necesita utilizar herramientas pero aseg rese de girar la perilla todo lo posible a mano Despu s de hacer esto afloje la perilla 1 4 de vuelt...

Страница 17: ...953 5737 Comun quese con el Servicio de Atenci n al Cliente llamando al 1 800 953 5737 Luz LED roja encendida Fallo el ctrico Soluciones Causa probable Problema V lvula Easy Quick Clear Soluci n de p...

Страница 18: ...entregar un n mero de Autorizaci n de Devoluci n de Producto RGA por las siglas en ingl s de Return Goods Authorization La unidad o partes defectuosas deben devolverse para la inspecci n de garant a u...

Отзывы: