24
25
Sprog
Sprog
2
PELLETS
-3
DRAUGH
Using keys 4 and 5, alter the supply of the pellets, from step -5 to 5.
Using keys 6 and 7, alter the draught in the chimney, from step -5 to 5.
Confirm with 3.
The changes indicate the percentage change from the standard set-
tings.
If combustion is poor, the value must be changed. Poor combustion may be due to the use of
lower quality pellets than those used in the standard tests of the pellet stove.
IMPORTANT!
THIS FUNCTION IS ONLY EFFECTIVE IF THE NECESSARY ADJUSTMENTS OF THE PELLET
STOVE HAVE BEEN COMPLETED DURING INSTALLATION
Automatic auger filling
To fill the auger automatically (when the pellet stove is commissioned the first time or if the
hopper runs out) the following steps must be taken:
1. Keep key 4 pressed down for 3 seconds. The text MENU01: SET CLOCK is shown
2. Press key 4 four times: the display shows : MENU05: STOVE STATUS.
3. Press key 6 to allow access: The display shows the following:
4. Press key 4 to activate the auger. Press 5 to deactivate.
5. Press key 3 to return to the main menu.
Leave the setting ”Auger 1” active, until pellets drop down into the burn pot.
Repeat several times if necessary, until you can see that the pellets are dropping into the burn
pot.
NOTE: this must only be done when the pellet stove is at CLEANING ENDED or OFF
2000
150°C
AUGER 0
STATUS
2000
150°C
AUGER 1
STATUS
IMPORTANT!
ONCE THE AUGER HAS BEEN FILLED, THE BURN POT MUST BE EMPTIED BEFORE THE
PELLET STOVE IS TURNED ON.
The auger is turned off
The auger is started
Lighting the pellet stove for the first time
Before the pellet stove turned on, the following procedure must be followed:
1. Check that the system is connected to a chimney approved by the chimney sweep.
2. Plug the power cable into the socket.
3. Set the switch behind the stove to 1.
4. Fill the pellet hopper with pellets that meet the quality requirements (see page 14)
5. Fill the auger as described in ”Automatic auger filling”
6. Press key P3 for 3 seconds.
The pellet stove enters the ignition phase.
The display shows the following texts:
•
START
•
AWAITING FLAME
•
FLAME RECOGNISED
•
OPERATION
During operation, the following settings must be checked:
•
SETTING POWER STEP (see page 22)
•
SETTING ROOM TEMPERATURE (see page 23)
•
ADJUSTING COMBUSTION (see page 23)
Overview of operation phases
PHASES
DESCRIPTIONS
CLEANING ENDED
The pellet stove is in the extinguishing phase, the cooling phase
has not yet completed.
START
The ignition phase has started. Pellets are being loaded into the
burn pot.
AWAITING FLAME
The ignition tube is about to light the pellets.
FLAME RECOGNISED
The flame in the burn pot is strong.
1 OPERATION
The pellet stove has completed the ignition phase, the power step
can now be changed.
MODULE
The set value of room temperature has been reached.
ECO STOP
The climate comfort function is activated, the set temperature has
been reached. The pellet stove has been extinguished.
TON
The room temperature has been interrupted or connected to an
external thermostat.
AWAITING/
RESTART/ COOLING
The pellet stove is in a cooling phase, waiting for the flue gas tem-
perature to cool down. COOLING - after which it will restart itself.
HOT SMOKE
The pellet stove has exceeded the maximum flue gas temperature
and will try to reduce it automatically by changing the power step
to P1.
OFF
The pellet stove is extinguished.