PTC fitting
Air line
Collar
Manual Control Using the Schrader Valve
If electrical power is lost or the system is inoperable, the suspension air springs can be inflated through the
suspension-mounted Schrader valve using an external air supply (gas station air or external air compressor).
Inflate to achieve the green zone suspension height before towing. Depress the Schrader valve to deflate
and reduce height.
Tips
• To ensure a proper seal, cut off the end of the air line just beyond the witness mark
before reinstalling in the fitting.
• If the fitting is leaking at the threads, it may be necessary to remove and reapply thread
sealant on the threads and reinstall 1 1/2 turns beyond finger tight.
Fixing Leaks on PTC Fittings
STEP 1
After insertion, check the PTC fitting connection by pulling on each line to verify a robust connection.
STEP 2
To release the air line from the connection, first release all air from the system. Push in on the air line
(STEP 1)
,
push the collar in
(STEP 2)
, and with the collar depressed, pull the air line out of the fitting
(STEP 3)
.
STEP 3
To reconnect, push the air line into the fitting and pull to verify a robust connection.