45
TriStar MPPT Operator’s Manual
Current Limit
The array power exceeds the rating of the controller. This alarm indicates that the TriStar MPPT
is limiting battery current to the maximum current rating.
RTS Open
The Remote Temperature Sensor is not connected to the controller. Use of the RTS is recom-
mended for proper battery charging.
Heatsink Temperature Sensor Open / Shorted
The heatsink temperature sensor is damaged. Return the controller to an authorized Morningstar
dealer for service.
Battery Sense Out of Range / Disconnected
A battery sense wire is disconnected. Inspect the battery sense connections. This alarm is set
when the voltage at the battery sense voltage differs by more than 5 volts from the voltage at the
battery terminals.
Uncalibrated
The controller was not factory calibrated. Return the controller to an authorized Morningstar
dealer for service.