40
Operation
4.3 Push button
The following functions can be enabled with the pushbutton (located on the front cover):
PUSH
• Reset from an error or fault.
• Reset the battery service indication if this has been activated in custom settings. A new
service period will be started, and the
fl
ashing LED’s will stop blinking. If the battery ser-
vice is performed before the LED’s begin blinking, the pushbutton must be pushed at the
time when the LED’s are blinking to reset the service interval and stop the blinking.
PUSH AND HOLD 5 SECONDS
• Request battery equalization manually. The TriStar MPPT will begin equalization in either
the manual or automatic equalization mode. Equalization will begin when there is suf
fi
cient
solar power to charge the battery up to the equalization voltage. The LEDs will blink the
sequence de
fi
ned in table 4-3 below to con
fi
rm that an equalize has been requested. The
equalization request will automatically stop per the battery type selected (see Section 4.4).
Equalization will only occur if the selected battery type has an equalization stage.
• Stop an equalization that is in progress. This will be effective in either the manual or auto-
matic mode. The equalization will be terminated. The LEDs will blink to con
fi
rm the equal-
ize has been cancelled as shown in table 4-3 below.
Pushbutton Action
SOC LED Indication
Manual Equalization Started
Green+Red / Green+Red / Green / Green
Stop Equalization
Green+Red / Green+Red / Red / Red
Table 4-3. Manual equalization LED indications
NOTE:
For multiple TriStar MPPT controllers on a MeterBus
TM
network, initialize a battery equalization
using the TriStar meter so that all controllers are synchronized.
REMARQUE :
Avec plusieurs contrôleurs TriStar MPPT sur un réseau MeterBusTM, initialisez une
compensation de batteries à l’aide de l’outil de mesure TriStar afi n de synchroniser tous les
contrôleurs.
Note that if two or more TriStar MPPT controllers are charging in parallel, each controller may
attempt to equalize on a different day. Systems with multiple controllers should only equalize
manually to ensure synchronization between controllers.
Содержание TriStar TS-MPPT-30