7.0 TECHNICAL SPECIFICATIONS
45
44
7.0
TECHNICAL SPECIFICATIONS
Electrical
Nominal system voltage
12 or 24 Vdc
Max. solar input voltage
30 or 60V
Max. solar current
6.5 or 10 or 20A
Battery voltage range
6 -15V or 6-30V
Self-consumption
< 8 mA
Voltage Accuracy
1.0 %
Transient Surge Protection
1500W per
connection
Protections (Solar & Load):
short circuit, over-current, reverse
polarity, high temperature, high voltage
Battery Charging
Regulation Method
4 stage PWM
Temp. Compensation Coefficient
12 V: -30 mV / °C
24 V: -60 mV / °C
(25°C reference)
Temp. Compensation Range
- 30°C to + 60°C
Temp. Compensated Set-points
Absorption
Float
Equalize
Battery Status LEDs
Falling V Rising V
G to Y
12.1
13.1
Y to G
Y to Flash R 11.7
12.6
R to Y
Flash R to R 11.5
Note: Multiply x2 for 24 Volt systems.
Note: Only SunSavers with load control display the Flashing Red LED
indication.
Battery Set-points (@ 25°C)
Sealed
12 V or 24 V
Flooded
12 V or 24 V
Absorption Voltage
14.1 V or 28.2 V 14.4 V or 28.8 V
Absorption Duration
3 hr
3 hr
Float Voltage
13.7 V or 27.4 V 13.7 V or 27.4 V
Equalize Voltage
none
14.9 V or 29.8 V
Equalize Duration
none
3 hrs
Equalize Calendar
none
28 days
Max. Regulation Voltage
1
15 V or 30 V
Low Voltage Disconnect
11.5 V or 23.0 V
Low Voltage Reconnect
12.6 V or 25.2 V
High Voltage Disconnect
15.3 V or 30.6 V
High Voltage Reconnect
14 V or 28 V
Start-Up LVD
11.7 V or 23.4 V
Instant LVD
10.0 V or 20.0 V
1
Not temperature compensated. 15 V @ 12 V nominal, 30 V @ 24 V nominal
NOTE: Temperature compensation increases regulation
voltage in cold temperature. A 15 V (30 V @ 24 V nominal)
maximum battery voltage limit prevents damage to
sensitive DC loads.
Environmental
Ambient Temperature Range
-40°C to +60°C
Storage temperature
-55°C to +80°C
Humidity
100% N.C.
Enclosure
IP10 (indoor)