MORNINGSTAR CORPORATION
15
2.0 GENERAL INFORMATION
14
This Class B digital apparatus complies with Canadian
ICES-003.
Cet appareil numerique de la classe B est conforme a la
norme NMB-003 du Canada.
3.0 INSTALLATION INSTRUCTIONS
3.1 General Installation Notes
• Read through the entire installation section before
beginning installation.
• Be very careful when working with batteries. Wear
eye protection. Have fresh water available to wash
and clean any contact with battery acid.
• Use insulated tools and avoid placing metal objects
near the batteries.
• Explosive battery gases may be present during charg-
ing. Be certain there is sufficient ventilation to
release the gases.
• Do not install in locations where water can enter the
controller.
• Loose power connections and/or corroded wires
may result in resistive connections that melt wire
insulation, burn surrounding materials, or
even cause
fire
. Ensure tight connections and use cable clamps
to secure cables and prevent them from swaying in
mobile applications.
• The SunSaver charging algorithm is compatible with
lead-acid or NiCd batteries.
NiMH, Li-ion, and other
battery chemistries are not compatible with the
SunSaver charging algorithm.
• The SunSaver Battery connection may be wired
to one battery or a bank of batteries. The following
instructions refer to a singular battery, but it is implied
that the battery connection can be made to either one
battery or a group of batteries in a battery bank.
2
3 .0