2.0  GENERAL INFORMATION

13

12

5 - Battery Status LEDs 

Provides approximate battery 

state-of-charge

 indication 

and also indicates when a system or load fault condition 

exists.

6 - Mounting Holes

Four (4) mounting holes

2.3 Regulatory Information

NOTE:  

This section contains important information for safety 

and regulatory requirements.

The SunSaver controller should be installed by a qualified 

technician according to the electrical regulations of the 

country in which the product will be installed.

SunSaver controllers comply with the following EMC 

standards:

•  Immunity:  EN61000-6-2:1999
•  Emissions:  EN55022:1994 with A1 and A3 Class B1
•  Safety:  EN60335-1 and EN60335-2-29 (battery    

chargers)

               

FCC requirements:

This device complies with Part 15 of the FCC rules.  

Operation is subject to the following two conditions:  (1) 

This device may not cause harmful interference, and (2) 

this device must accept any interference received, including 

interference that may cause undesired operation.

Changes or modifications not expressly approved by 

Morningstar for compliance could void the user’s authority to 

operate the equipment.

Note:  

This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to Part 

15 of the FCC rules.  These limits are designed to provide 

reasonable protection against harmful interference in a 

residential installation.  This equipment generates, uses, and 

can radiate radio frequency energy and, if not installed and 

used in accordance with the instruction manual, may cause 

harmful interference to radio communication.  However, 

there is no guarantee that interference will not occur in a 

particular installation.  If this equipment does cause harmful 

interference to radio or television reception, which can be 

determined by turning the equipment on and off, the user is 

encouraged to try to correct the interference by one or more 

of the following measures:

•  Re-orient or relocate the receiving antenna.
•  Increase the separation between the equipment and 

receiver.

•  Connect the equipment into an outlet on a circuit       

different from that to which the receiver is connected.

•  Consult the dealer or an experienced radio/TV        

technician for assistance.

2

2 .0

Содержание S-20L-24V

Страница 1: ...nual www morningstarcorp com MORNINGSTAR World s Leading Solar Controllers Inverters SUNSAVER PV SYSTEM CONTROLLERS SunSaver Models Included in this Manual SS 6 12V SS 6L 12V SS 10 12V SS 10L 12V SS 1...

Страница 2: ...ermine the highest expected array Voc as defined by the lowest expected ambient temperature for the system location CONTENTS 1 0 Safety Information 4 2 0 General Information 10 2 1 Overview 10 2 2 Fea...

Страница 3: ...urces of power to the controller before installing or adjusting the SunSaver There are no fuses or disconnects inside the SunSaver Do not attempt to repair Install external fuses breakers as required...

Страница 4: ...battery bank Mount the controller at least 3 ft 1 m away from vented batteries unless separated by a barrier or located in a separate compartment Installation in Hazardous Locations THIS EQUIPMENT IS...

Страница 5: ...de batteries du m me type fabricant et ge Ne fumez pas proximit du groupe de batteries Les connexions d alimentation doivent rester serr es pour viter une surchauffe excessive d une connexion desserr...

Страница 6: ...ove Jumper Wire for Flooded Battery 12 V BATTERY STATUS TEMP SENSOR CHARGING STATUS See Operator s Manual Nominal Rating 12 Volts dc Max Input 30 V Solar 6 5A Battery 6 5A Load 10 0A indoor use only U...

Страница 7: ...modifications not expressly approved by Morningstar for compliance could void the user s authority to operate the equipment Note This equipment has been tested and found to comply with the limits for...

Страница 8: ...ufficient ventilation to release the gases Do not install in locations where water can enter the controller Loose power connections and or corroded wires may result in resistive connections that melt...

Страница 9: ...Slow Switching charging PWM charging is the default regulation method and is the method recommended for most systems Slow Switching regulation should only be selected if noise or interference exists i...

Страница 10: ...Les vapeurs des batteries sont inflammables et corroderont et d tru iront les circuits du SunSaver PRUDENCE Endommagement de l quipement Assurez une ventilation suffisante en cas d installation du Su...

Страница 11: ...during installation When disconnecting solar input must be removed first before disconnecting battery See caution below NOTE The SunSaver is a negative ground controller Any one negative conductor ca...

Страница 12: ...se only Use 75 C Copper Conductors Only CONFORMS TO ISA12 12 01 CERTIFIED TO CAN CSASTD C22 2 NO 213 1992 Class I Division 2 GroupsA B C D Hazardous Loc Temp Code T5 RoHS MORNINGSTAR S S 20L UN AVER S...

Страница 13: ...olts to power the SunSaver 12V or 24V models Connect the battery to the SunSaver Refer to the wire gauge chart on page 43 of this manual for correct wire size Use 75 C copper wire If required the nega...

Страница 14: ...bles du syst me WARNING Risk of Damage Connecting the solar array to the battery terminal will permanently damage the SunSaver AVERTISSEMENT Risque d endommagement La connexion du r seau solaire sur l...

Страница 15: ...ad 20 0A Max Ambient 65 C indoor use only Use 75 C Copper Conductors Only CONFORMS TO ISA12 12 01 CERTIFIED TO CAN CSASTD C22 2 NO 213 1992 Class I Division 2 GroupsA B C D Hazardous Loc Temp Code T5...

Страница 16: ...f the SunSaver does not power up or a flashing LED error sequence exists refer to Section 5 0 Troubleshooting 4 0 OPERATION 4 1 LED Indications STATUS LED The Status LED indicates charging status and...

Страница 17: ...On Battery Missing Load Off Table 3 Battery SOC LED definitions NOTE An error condition exists if multiple Battery SOC LEDs are flashing See Section 5 1 Error Indications for more information 4 2 Bat...

Страница 18: ...pecial charging function to recover batteries that have discharged too low If the terminal voltage of the battery is greater than 1 Volt the SunSaver will detect the battery and provide approximately...

Страница 19: ...mage the load Always re check load connections before applying power The SunSaver will go straight to LVD on start up if the battery voltage is at or below 11 7V 23 4V 4 0 4 4 Protections Solar Overlo...

Страница 20: ...atsink temperature has exceeded 85 C and the solar and load is disconnected The SunSaver will automatically reconnect when the heatsink cools to 80 C High Voltage Disconnect Battery Status LED R G seq...

Страница 21: ...Yellow LED is on then Red and Green LED are on 5 2 Common Problems Problem No LED indications Solution With a multi meter check the voltage at the Battery terminals on the SunSaver and the Solar term...

Страница 22: ...NOT LIMITED TO LOST PROFITS DOWN TIME GOODWILL OR DAMAGE TO EQUIPMENT OR PROPERTY 7 0 TECHNICAL SPECIFICATIONS 6 0 WARRANTY and CLAIM PROCEDURE WARRANTY CLAIM PROCEDURE 1 Before proceeding please refe...

Страница 23: ...e Only SunSavers with load control display the Flashing Red LED indication Battery Set points 25 C Sealed 12 V or 24 V Flooded 12 V or 24 V Absorption Voltage 14 1 V or 28 2 V 14 4 V or 28 8 V Absorpt...

Страница 24: ...E WITH DISTRIBUTED ENERGY SOURCES FIRST EDITION REVISION THROUGH AND INCLUDING NOV 7 2005 CSA C22 2 No 107 1 01 3094762 RoHS Compliant 2002 95 EC 12 VOLT NOMINAL WIRE CHART Amps One way Wire Distance...

Страница 25: ...g Solar Controllers Inverters www morningstarcorp com Specifications subject to change without notice Designed in the U S A Assembled in Taiwan 2017 Morningstar Corporation MS 001272 v3 3 THIS PAGE IS...

Отзывы: