Operation
EcoBoost MPPT Operator's Manual
31
30
4.0
High Temperature Current Limit
The EcoBoost MPPT will limit the solar input current if the
heatsink temperature exceeds safe limits. Solar charge
current will be tapered back (to 0 amps if needed) to reduce
the heatsink temperature. The EcoBoost MPPT is designed
to operate at full rated current at the maximum ambient
temperature. This alarm indicates that there is insufficient
airflow and that the heatsink temperature is approaching
unsafe limits. If the controller frequently reports this alarm
condition, corrective action must be taken to provide better
air flow or to re-locate the controller to a cooler spot.
High Input Voltage Current Limit
The EcoBoost MPPT will limit the solar input current as
the solar array Voc approaches the maximum input voltge
rating. The array Voc should never exceed the 120 volt
maximum input voltage - see the array voltage de-rating
graph in Appendix.
Current Limit
The array power exceeds the rating of the controller. This
alarm indicates that the EcoBoost MPPT is limiting battery
current to the maximum current rating.
RTS Open
The Remote Temperature Sensor is not connected to the
controller. Use of the RTS is recommended for proper
battery charging.
Heatsink Temperature Sensor Open / Shorted
The heatsink temperature sensor is damaged. Return the
controller to an authorized Morningstar dealer for service.
Uncalibrated
The controller was not factory calibrated. Return the
controller to an authorized Morningstar dealer for service.
4.6 Custom Settings
4.6.1
Adjusting Set-points with the Meter Display
The EcoBoost MPPT is available in metered and
non-metered versions. The metered model allows:
• Custom programming directly from the unit.
• Extensive settings adjustment and information as shown
partially in Figure 4-2 below.
Figure 4-2. Simplified Meter Map.
Start Lighting Test
Load Disconnect
Factory Reset
Reset Control
Backlight Timer
Backlight
Target Voltage
Battery Temp.
Display Screens and Programming
Models:
EcoBoost-20M
EcoBoost-40M
EcoBoost-30M
Main Screens
Daily Charging Stage - Time
Daily Charge Transferred -
Battery and Load
Solar Current - Battery
Current - Load Current
Daily Max / Min
Battery Voltages
STATUS
HISTORY
See Complete History
Screens Online, or in
Manual Insert
SYSTEM
DISPLAY
SETTINGS
COMMANDS
Faults
Load / Light State
Charge State
Input Voltage
Alarms
CUSTOM PROGRAMMING:
To
Programming
Screens
Clear KWh
Records
Graphs
Error Log
Battery Sense
Hour Meter
Last Equalization
Brightness
Auto Scroll
Contrast
Auto Return
Auto Scroll Timer
Language
Temp. Units
See Complete
Programming Screens
Online or in Manual Insert
See Complete
Programming Screens
Online or in Manual Insert
Clear Resettable Ah
Clear Total Ah
Serial No.
Firmware Version
Battery Type
Absorption Voltage
Float Voltage
EQ Voltage
Input Mode
System Voltage