35
MB 200
rev.0.1UL ID01460
6. INSTALLATION
CAUTION!
The machine must be installed by K.G.S. technicians or by
personnel authorized by K.G.S.
6.1 PhYSICAL ChARACTERISTICS OF ThE POSITIONING AREA
In the vicinity of the area where the machine is positioned, power sources of electric and pneumatic
power must be prepared in accordance with the requirements in the marking label. Provide sufficient
space for normal use, for the maintenance of the machine, for any command and any attached
equipment (see the positioning section diagram). The site chosen must not be next to flammable
material deposits, nor to areas where processes that can create flammable or explosive atmospheres
are carried out.
The machine must be placed in a covered area and protected from direct contact with atmospheric
agents.
For the operations of installation it is necessary to provide a manoeuvring area adequate to the size
of the machine parts and to the selected lifting means, by paying attention to the presence of any
obstacles (other machines, walls or such) along the path to take.
6.2 FLOOR
The machine does not require special foundations. The availability of industrial flooring must be
guaranteed. The binder rests on 4 feet diameter of 100 mm and its weight is 250 kg.
6.3 LIGhTING
Good lighting is required in order to carry out the processing and maintenance of the machine in a
safe manner. The ambient lighting should have a normal value to allow working operations without
causing hazards because of shaded areas.
6.4 ENVIRONMENTAL CONDITIONS
The values of temperature and humidity must be within the values indicated in the table below.
In the case where the plant is used in corrosive atmosphere environments, it is important to intervene
in the maintenance of the machine with appropriate timing so as to avoid excessive wear of the
components.
MIN
MAX
Room temperature
5°C
40°C
Relative humidity
20%
80%
5500 NE Moore Court
Hillsboro, OR 97124
Toll Free: 1-800-944-4573
Local: 503-640-5920