16
MB 200
rev.0.1UL ID1460
5.2 ELECTRICAL SPECIFICATIONS
Power Supply
220 ─ 230 V 50/60 Hz, 1 ~ + N + PE
Max Power Consumption
3,5 Kw
Fuse Protection
By the customer, on the power supply line 16 A
Class differential protection A 300mA
5.3 PNEUMATIC SPECIFICATIONS
Ensure that the equipment and pneumatic circuits can operate reliably, efficiently and safely, it is
necessary that the compressed air used to power the pneumatic system has the following quality
requirements in accordance with DIN ISO 8573-1:
▪
Quality of the supplied air CLASS 3
▪
Dust: 5 micron - 5 mg/m
3
▪
Water: -20°C - 0,88 g/m
3
▪
Oil: 1 mg/m3
The compression system air upstream of the binding machine must be of the type with dryer.
Periodically check the quality of the compressed air supplied to the machine and operating values.
Supply pressure
The pneumatic air supply of the user must ensure, to the inlet fitting of the compressed air in
the binder, the following values:
▪
7 bar;
▪
ensure a consumption of air equal to 160 Nl/min
▪
Air Quality: Class 3
Pneumatic features:
Air consumption 100 Nl/min
Gauge input 6 bar
Minimum pressure 5.5 bar
Input gauge 6 mm
The connecting pipe to the compressor diameter of 6 mm is not supplied with the machine.
We recommend a compressor with automatic condensate drain. To avoid the weekly check
of the presence of water inside the tank of the compressor.
If the compressor is placed within the company we recommend the purchase of a silent
compressor.
5500 NE Moore Court
Hillsboro, OR 97124
Toll Free: 1-800-944-4573
Local: 503-640-5920