Programmable Smart HART 
Temperature Transmitter and Display

Figure 15.

  THZ

2

 and TDZ

HART Communicator Configuration Menu Summary

Online Menu

1 Model 
2 Device Setup
3 PV
4 AO
4 LRV
6 URV

1 Process Variable

2 Setup

3 Diagnostic &
   Services

4 Review

1 PV
2 % Range
3 AO
4 Term. Temp

Setup

1 Configure
   Sensor

2 Configure
    Options

3 Configure
   Range

4 Configure
   Output

5 Configure 
   Dev Info

6 *Configure
   Display

Configure Sensor

Sensor Type 

1 RTD2W
2 RTD3W
3 RTD4W
4 mV
5 OHMS2W
6 OHMS3W
7 OHMS4W
8 T/C
9 T/C w/RJC
10 Potentiometer

RTD

Thermocouple

1 T/C J
2 T/C K
3 T/C E
4 T/C T
5 T/C R
6 T/C S
7 T/C B
8 T/C N
9 T/C C

Sensor Information 

1 LSL
2 USL
3 Min Span

Configure Options

1 EGU Selecton
2 EGU
3 Filter
4 Running Average 
5 Broken Wire
6 AO URV
7 AO ORV 
8 Fail Mode
9 Fail Mode AO
Smart Range Selection

Configure Range 

1 Smart Ranging
2 Input Capture

Smart Ranging

Set the:

1 4mA
2 20mA
3 Exit

Configure Output

1 Analog output
2 HART output

Analog Output

1 Output Zero
2 Output Full
3 Output Trim
4 Output Trim Reset

HART Output

1 Poll addr
2 Burst mode
3 Burst option

Configure Dev Info

1 Tag
2 Descriptor
3 Message
4 Date
5 Final asmbly num
6 Device id
7 Hardware rev

Configure Display

1 Mode
  (PV, mA, Toggle, %) 
2 Decimal Places
   (1, 2, 3, Auto) 
3 Custom Label
   (Disabled/Enabled)
4 Label Displayed

Diagnostic &
Services

Review 

1 Device
   Parameters

2 Device
   Information

Sensor Trim

1 Sensor Trim Mode
2 Sensor Trim
3 Sensor Trim Reset

Loop Test

1 4mA
2 20mA
3 Other
4 End

Device Parameters

Model
Measure Mode
Input Type
Sensor Serial Number 
Filter
Running Average
Broken Wire
Broken Wire Level
EGU
LRV
URV
LSL
USL
Min Span
PV Damping
Sensor Trim Mode
AO URV
AO ORV
Fail Mode
Fail Mode AO
Smart Range Selection

Device Information

Tag
Descriptor
Message
Date
Dev id 
Universal rev
Fld dev rev
Software rev
Hardware rev
Physicl signl code
Poll addr
Burst mode 
Num req preams

Key

*If unit is TDZ 2

1 LSL
2 USL 
3 Min Span
4 Sensor LRV 
5 Sensor LRV 
   Scaled to
6 Sensor URV
7 Sensor URV  
   Scaled to 
8 Scaling EGU

Smart Ranging 

(If Scaling Enabled)

Smart Ranging

(If Custom Curve 

Enabled)

Process Variable

1 Sensor Type
2 Sensor Serial 
   Number
3 PV Damping
4 Sensor 
   Information

If Scaling  
Enabled

If Custom Curve 
Enabled

1 PT3850 100
2 PT3850 200
3 PT3850 300...

13 NI 672 120
14 CU 427 9.035

1 LSL
2 USL 
3 Min Span
4 CC Points
5 Custom Curve  
   LRV 
6 Custom Curve  
   URV 
7 CC EGU

1 LSL
2 USL 
3 Min Span
4 LRV 
5 URV

1 Test device
   (Status)
2 Sensor Trimming
3 Loop Test

% RANGE = Output Current  
in % of Span 
# PREAMBLES = Number of Preamble
Characters 
AO = Output Current 
AO ORV = Analog Output  
Over Range Value 
AO URV = Analog Output  
Under Range Value 
DAMP = Damping Value 
DEV ID = Device Identification 
DIAG = Diagnostic 
LRV = Lower Range Value 
MAX VALUE = Maximum Process Value  
MIN VALUE = Minimum Process Value 
OFFS = Offset 
POLL ADDR = Polling Address 
URV = Upper Range Value 

1

2

3

4

A

B

C

D

E

F

5

6

Device Setup

Содержание TDZ2

Страница 1: ...THZ2 TDZ2 THZ 2 TDZ 2 Programmable Smart HART Temperature Transmitter and Display ay 201 235 797 01 TPRG Programmable Smart HART Temperature Transmitter and Display...

Страница 2: ...he THZ2 and TDZ2 11 Installing the Configuration Software 11 Connecting the THZ2 or TDZ2 to the PC 12 Necessary Equipment Table 12 PC Configuration Software Summary 15 Menu and Tool Bar Legend 16 Conf...

Страница 3: ...tion 32 Mounting the THZ2 and TDZ2 32 Making the Electrical Connections 32 Recommended Ground Wiring Practices 32 CE Conformity 33 Installation in Hazardous Locations 34 Operation 35 HART Protocol 35...

Страница 4: ...l configuration parameters are available through the PC Configuration Software The second method is to connect a HART Communicator and HART modem into your process loop You must ensure that your commu...

Страница 5: ...o 4 0mA and 20 to 23 6mA for input under over range 25mA maximum hardware limit T C Input Impedance 40Mohms nominal RTD Ohms Excitation 250 microamps 10 RTD Lead Wire Resistance Maximum RTD resistance...

Страница 6: ...C 346 to 1418 F 270 to 1390 C 454 to 2534 F 270 to 1013 C 454 to 1855 4 F 270 to 407 C 454 to 764 6 F 50 to 1786 C 58 to 3246 8 F 50 to 1786 C 58 to 3246 8 F 200 to 1836 C 392 to 3336 8 F 270 to 1316...

Страница 7: ...C J K N C E T C T R S B Pt RTD 100 200 300 ohms Pt RTD 400 500 1000 ohms Ni 120 ohms Cu 9 03 ohms mV 250 1000 62 5 250 31 25 62 5 Resistance 1 4kohms 0 25 1kohms 0 125 0 25kohms 5 yrs 0 019 0 104 Sta...

Страница 8: ...sing Dimensions FRONT VIEW SIDE VIEW 61mm 2 4 in PS PS 1 2 3 4 5 COM TDZ 83mm 3 2 in 62mm 2 4 in 64mm 2 5 in 66mm 2 5 in 76mm 3 0 in 43mm 1 7 in 18mm 0 70 in 2 Figure 3 THZ2 DIN Dimensions 138mm 5 4 i...

Страница 9: ...isplay Figure 4 BH Housing Dimensions For use with the TDZ2 PS COM PS 1 2 3 4 5 TDZ ADDR 0 602 78 DEG C 68mm 2 6 in GND 1 2 NPT 102mm 4 0 in 84mm 3 3 in 68mm 2 6 in 64mm 2 5 in 10mm 0 3 in 124mm 4 8 i...

Страница 10: ...C models 61mm 2 4 in 10 32 Mounting Holes 2 51mm 2 0 in Safety Lock LH2 only Metal Tag BOTTOM INSIDE 2 INCH PIPE MOUNTING HARDWARE 30mm 1 1 in DIA 72mm DIA 2 8 in Instrument Mounting Holes 40mm 1 5 in...

Страница 11: ...r TDZ2 with either a standard HART Communicator or our PC software Figures 7 and 8 depending upon your instrument s housing and Table 5 provide the information you need to configure your unit Using a...

Страница 12: ...to create configuration files using the software The Configuration Program can be run without connecting a transmitter and most parameters can be set without benefit of input from a sensor or transmit...

Страница 13: ...tiometer Input 2 3 4 1 Input Hook Up Connections HART Modem connects to serial COM port of PC 12 24Vdc Power Supply THE HART Communicator or the PC can be connected at any point on the output side of...

Страница 14: ...1 4 3 2 Potentiometer Input 12 24Vdc Power Supply THE HART Communicator or the PC can be connected at any point on the output side of the loop Total loop resistance must equal between 250 and 1100 oh...

Страница 15: ...the appropriate part of the THZ2 s and the TDZ2 s configuration See corresponding sections of this manual for additional information regarding these tabs Once the default configuration has been saved...

Страница 16: ...download or upload monitoring must be stopped To do this click Stop in the Monitoring dropdown menu or click the Stop Monitoring icon on the Tool Bar Input Figure 10 Input Tab Input Type Select your i...

Страница 17: ...TDZ2 send random microamp pulses through input wiring to check for broken wiring or a burned out sen sor To utilize Broken Wire Detection check the Enabled box If a failure is detected a message will...

Страница 18: ...cations To customize your display and set your own EGU open the Display screen and use the Custom Label feature Note Once you have configured all parameters download to the unit by selecting Download...

Страница 19: ...t into the No Of Points text box 3 In the Custom Curve Y Range text boxes enter the values you wish displayed and represented as your 4 20mA span when your input is at its upper and lower ranges 4 Typ...

Страница 20: ...g Download in the Transfer dropdown menu located in the Menu Bar Or click the button in the Tool Bar Output Current While in monitoring mode this dis plays the present output value Trimming Output Tri...

Страница 21: ...n of the DD you must send the Communicator to Moore Industries To do this contact our Customer Service department for a Returned Material Authorization RMA Include Moore Industries configuration sheet...

Страница 22: ...ices Review 1 Device Parameters 2 Device Information Sensor Trim 1 Sensor Trim Mode 2 Sensor Trim 3 Sensor Trim Reset Loop Test 1 4mA 2 20mA 3 Other 4 End Device Parameters Model Measure Mode Input Ty...

Страница 23: ...e Upper Sensor Limit USL Lower Sensor Limit LSL and minimum span of the selected sensor type B Configure Options You may configure the THZ2 and TDZ2 options listed below from the this menu 1 EGU Selec...

Страница 24: ...tached sensor 2 USL Displays the upper sensor limit USL of the attached sensor 3 Min Span Indicates the allowable minimum difference between the upper range value URV and lower range value LRV 4 CC Po...

Страница 25: ...nded to do so The Master device receives the data more frequently than if it were only polling the transmitter achieving a higher data trasnfer rate Note For Fisher Rosemount HART Communicator Model 2...

Страница 26: ...d accuracy and to trim other instruments in the loop Your output will be a current value in mA equal to the value you input You can check the other current devices on the loop and calibrate them to th...

Страница 27: ...es Range Values 1 PVLRV 2 URV 3 PVLSL 4 USL Device Information 1 Distributor 2 Model 3 Dev ID 4 Tag 5 Date Sensors 1 PV 2 PV SNSR 3 Sensor Information Signal Condition 1 SNSR DAMP 2 URV 3 AI LRV 4 AI...

Страница 28: ...r an individual transmitter the units of measurement the upper and lower range and sensor values and a damping time between 0sec and 30sec 3 Analog Output The Analog Output menu displays the analog ou...

Страница 29: ...ed in every response message However they do not detail the transmitter specific Additional Status Information that is returned in the data portion of the response to HART Command 48 You may ac cess t...

Страница 30: ...r has been removed and reapplied resulting in the reinstallation of the setup information The first command to recognize this condition will automatically reset this flag This flag may also be set fol...

Страница 31: ...ror ADC Error Bad custom curve Front end Back end communications failure Set to zero Set to zero Set to zero Set to zero Table 10 HART Command 48 Data Bytes Description Status Byte 0 1 2 3 4 5 Status...

Страница 32: ...r Recommended Ground Wiring Practices Moore Industries recommends the following ground wiring practices Any Moore Industries product in a metal case or housing should be grounded The protective earth...

Страница 33: ...e with the proper wire The end of each conductor should be stripped no more than 8mm 0 31 in The end of the stripped wire should be tinned with solder or inserted into a ferrule and crimped before bei...

Страница 34: ...he Models THZ2 and TDZ2 Temperature Transmitters shall be installed in an enclosure which maintains an ingress protection of IP54 and meets the enclosure requirements of EN60079 0 and EN60079 15 2 The...

Страница 35: ...configuration tool to set up the transmitter periodically view its real time process measurement or view its operating and diagnostic information from a loop termination point Digital Signal One of t...

Страница 36: ...nd Class III environments For applications in Canada adhere to the Canadian Electric Code C22 1 most current publication on I S installationguidelines For CENELEC ATEX and IECEx applications adhere to...

Страница 37: ...TERIAL 002 SILVER IDENTIPLATE MII P N 200 301 00 DIE CUT AS SHOWN ABOVE REFER TO LABEL SPEC DRAWING 200 301 00 COMPUTERIZED LABEL 200 251 2207 A 1 1 Gus H Elias INITIAL RELEASE REAR ID LABEL TDZ2 HP 4...

Страница 38: ...200 251 2208 IN THE LEGI 93 LABEL MACHINE COMPUTER HARD DISK 3 MATERIAL 002 SILVER IDENTIPLATE MII P N 200 304 00 DIE CUT AS SHOWN ABOVE REFER TO LABEL SPEC DRAWING 200 304 00 COMPUTERIZED LABEL 200...

Страница 39: ...E REM EDIES FOR BREACH OF ANYWARRANTY CONCERNINGTHE GOODS OR SERVICES SHALL BE FOR THE COMPANY AT ITS OPTION TO REPAIR OR REPLACE THE GOODS OR SERVICES OR REFUND THE PURCHASE PRICE THE COMPANY SHALL I...

Отзывы: