18
Rev. 1.0
0006302011
SSM23C User Manual
+86-400-820-9661
Do not connect the output to more than 30 volts. The current through the output terminal
must not exceed 100mA.
5 – 24 volt
Power Supply
+
-
Connecting a Sourcing Output
PLC
5 – 24 volt
Power Supply
+
-
Driving a Relay
1N4935 suppression diode
relay
SSM23C
SSM23C
OUT+
OUT+
OUT-
OUT-
IN
COM
5 – 24 volt
Power Supply
SSM23C
Connecting a Sourcing Output again
PLC
OUT+
OUT-
IN
COM
-
+
5 – 24 volt
Power Supply
Load
SSM23C
+
-
Connecting a Sinking Output
OUT+
OUT-