RS03/06-S/Q Hardware Manual
RS03/06-S/Q Hardware Manual
21
9 / 28 / 2015
+86-400-820-9661
3.3 Connecting to the PC using RS-232
The RS series step servo drive and motor are shipped with a 1.5 meters RS-232 communication
cable. The DB9 connector is used to connect to PC. The small end is a crimping connector used
to connect to the drive.
Located the RS series step servo drive and motor within 1.5 meters of the PC. Plug the DB9
connector into the serial COM port of the PC. Plug the small end crimping connector into the RS-
232 port of the drive. Do not hot plug.
If the PC doesn’t have a RS-232 serial port, a USB to RS232 converter will be needed. You can
contact MOONS’ to get a USB to RS-232 converter.
GND TX
+5V RX
J5
RS03/06-S/Q RS-232 Comm port
(View from the driver side)
Driver
Connection
GND
Connects to host GND
TX
Connects to host RX
+5V
Connects to host +5V
RX
Connects to host TX