0688-SOM-00001, Rev: 02
© Tritech International Ltd.
2.2 Powering the Bathy
The SeaKing 700 Series units are designed to work from a smoothed DC power supply.
If using a rectified transformer PSU, the output of the PSU must have a filter capacitor of not less than 470μF, for
each unit being powered.
If an unregulated PSU is used, the voltage value measured during power on/off and running conditions at the
unit should be within the voltage range specified for the system.
If powering the unit(s) down a long lead or umbilical, the maximum recommended resistance of the power line
must not exceed 10Ω for one unit, 5Ω for two units and 3Ω for three units.
2.3 Electrical Connections
The SeaKing 700 is typically supplied with a 1meter polyurethane
jacketed cable whip, fitted with a Tritech connector. Depending on the
specification of the system, the cable will either need to be terminated
to a suitable connector or may be supplied already terminated.
The standard Tritech connector may be disconnected from the unit
by unscrewing the four retaining screws and removing the connector
from the water block that is fitted to the end-cap. Do not remove the
water block.
While the cable is removed the exposed connectors should be fitted
with appropriate blanking caps to prevent the ingress of dirt or
moisture.
For devices fitted with non-Tritech connectors this procedure will vary.
For information on Tritech Standard wiring, connectors and pin-outs
please refer to Section 2.6 of this manual.
2.4 Connecting an Altimeter
The Bathy is designed to directly interface with a Tritech
PA500/06 altimeter. Connection is made to the Bathy Aux
Port using a standard Tritech double ended S01226 (R/A
to Str) interconnect cable.