5. Optimising the SK700 V7
5.1
System Check
The SeaKing 700 series heads should be checked for serviceability on the bench prior to undertaking any testing
underwater. Before applying power to the unit ensure that it is in good physical condition with no damage to
the sensors or housing.
The unit should be wired up and installed in exactly the same manner as it is intended to be used (i.e. on an ROV/
AUV) and connected to the surface computer. Power should then be applied.
Note
The device will dissipate a small amount of heat but this will not cause any
overheating problems if left running continuously in air or water.
5.2 Pre-dive Setup
Before deploying the sensors, start Seanet Pro and ensure that the system has been configured as follows:
•
Enter or check the Latitude
•
Enter or check Density (“Mean Relative Density”, default: 1.029g cm-3)
•
Enter or check V.O.S. (“Velocity of Sound”, default: 1475.0m s-1)
•
Enter Barometer (“Barometric Pressure”, default: 1000mbar)
•
Set all offsets (see Section 3.8, “Bathy Offsets”)
Options 1 to 4 are found in the Environment setup page (select Settings menu and then Environment). Option
5 is found by right-clicking on the main Bathymetric display and selecting Offsets.
Note
For the above options to be available it may be necessary to open the
Bathymetric screen by selecting Single Bathy (or similar) from the Applications
menu.