13
0688-SOM-00001, Rev: 02
© Tritech International Ltd.
4.1 Seanet Pro Operation
The Following section covers basic operation within SeaNet Pro. The SeaKing 700 series can be operated alongside
other devices in a multi-window application. For this example we will focus on the Single Bathy Application.
4.2 Main Screen
In the Applications menu at the top of the window, select “Single Bathy” to bring up the main Bathy interface
screen. Below is brief overview of the Bathy Application window.
1
8
9
7
3
2
4
5
6
1.
Main Seanet Menu-
This accesses the global
functions of Seanet Pro. Here you will also find
environmental offsets and configuration for devices as
well as the ability to load and playback stored log files.
2.
Bathymetric Settings Bar-
Quick access to some
of the basic functions of the bathy. To the left is
the Application tools button which accesses the bathy
setup and configuration. See section 3.9 for full details
on the Application Tools Menu. Next is the start/stop
sensor button.
3.
Logging Short-
Cuts- Logging controls to load
existing log files, Start and stop a new log. The
gears icon accesses the log settings panel to select file
destinations
4.
Print Bar-
Print, Quick Print and Print setup
options for printing the screen data.
5.
Side Bar Short-
cut- Opens a side bar which can
be used as an events logger or to store project
specific information to the log.
6.
Screen Capture-
Seanet Pro has it’s own screen
capture built in. Basic start/stop and setup can
be found here.
7.
Depth and Altitude -
Text boxes that display
live depth and altitude reading . Note that “NA” is
displayed when no Altimeter is connected.
8.
Bathymetric Data-
The system displays sensor
measurements for VoS, Density, Salinity, pressure
and temperature.
9.
System information bar-
Seanet
system
information including local time and com status
are displayed.
The Bathy Application generates a rolling display showing depth against time. The two main toolbars used
consist of the data display bar (running horizontally across the top of the bathy application), and the Seanet
controls short-cut bar (running vertically down the LHS of the display). There are two main toolbars, one long
the top of the screen and one vertically on the left of the depth profile.