background image

XT0016

5

Installation

RX 200  

ON/OFF Switch Installation

RX 200  

Battery Holder Installation

D. Main ON/OFF Switch Installation:

1.Position the Main/off Switch bracket on the right leg of the firebox.
2. Using the two selftapping screws supplied attach the bracket. 
3. Feed the switch and the wires through the slot in the bracket as 

shown and install the switch to the bracket. See Figure 21.

4. Secure the wires to the floor of the fireplace using the supplied cable 

tie and cable tie mounts.

5. Attach the "Main ON/OFF" sticker supplied to the switch bracket.

E. Battery Holder Installation:

1. Secure the battery holder to the fireplace floor using the supplied 

velcro strips. See Figure 22.  

  Note: The velcro strips act as an electrical isolation, do not attach 

the battery holder to any metal part without using the velcro strips, 

or the control module will be damaged.

2. Connect the red and black wires from the battery holder to the red 

and black wires from the valve harness. See Figure 23.

Figure 18

 Attach switch bracket to front of fireplace

Figure 19

 Attach switch bracket to front of fireplace

Figure 20

 Attach switch to bracket.

Figure 21

 Attach switch to bracket.

Figure 22 

Battery holder

Figure 23 

Battery holder wires

Содержание Proflame 2 RX 300 LP

Страница 1: ...Load with Remote THIS KIT IS FOR USE WITH THE FOLLOWING MODELS RX200 B34DT 2 F B34 TOP VENT ELECTRONIC IGNITION IPI B34DR 2 F B34 REAR VENT ELECTRONIC IGNITION IPI B38DT 2 F B38 TOP VENT ELECTRONIC IGNITION IPI B38DR 2 F B38 REAR VENT ELECTRONIC IGNITION IPI PL38DFN F PL38 ELECTRONIC IGNITION IPI PL38DFL F PL38 ELECTRONIC IGNITION IPI PL42DFN F PL42 ELECTRONIC IGNITION IPI PL42DFL F PL42 ELECTRONI...

Страница 2: ...it RFK3002R or RFK3004R required 5 Battery backup for the main burner during power outage Before You Begin Ensure that the power supply has been turned off at the breakerorfusebeforebeginning the installation Shut off the gas supply at the shut off valve and ensure that the main burner and pilot light have been turned off and the fireplace has been cooled off for at least two hours before installa...

Страница 3: ... and Sensor Wire from connectors X2 and X3 of the control module 3 Disconnect the wall switch harness from X4 Control Module and discard 4 Remove the Valve Harness from X5 of the control module 5 Remove the connector from X1 of the control module 6 Remove the control module from firebox compartment and discard Note module is attached by velcro strips Figure 3 Powercord in PPO box Figure 4 Control ...

Страница 4: ...alve body Use a torque screw driver with Torx T20 bit to tighten the two screws to a torque setting of 25 lb in 5 5 Install the enclosed identification label to the valve body Figure 12 G Figure 11 Stepper Motor Installations Figure 12 Label Installation Figure 13 Identification Label NG Figure 14 Identification Label LP Figure 15 New Control Module Figure 16 X1 plug on control module 3 Connect th...

Страница 5: ...N OFF sticker supplied to the switch bracket E Battery Holder Installation 1 Secure the battery holder to the fireplace floor using the supplied velcro strips See Figure 22 Note The velcro strips act as an electrical isolation do not attach the battery holder to any metal part without using the velcro strips or the control module will be damaged 2 Connect the red and black wires from the battery h...

Страница 6: ...and ensure no leak 5 Turn the fireplace ON and modulate the flame using the remote control and ensure proper operation see Proflame 2 Operation and Maintenance Manual XG0677 Blue Back lit LCD display On Off Key Thermostat Key Up Down Arrow Key Mode Key Figure 24 Proflame Remote Control G Operation with MAIN Power 1 Remove the four batteries from the battery holder 2 Plug the Control Module Power c...

Страница 7: ...ially recovered asheatintothebuilding soitdoesnotwasteasmuchenergyasrunning a pilot in the off season A connector is supplied with this unit that can be plugged into the wire harness connected to the controller This Jumper Cable gives the Remote Control the ability to operate the CPI IPI switch and set the unittooperateineithercondition CPImeans ContinuousPilotIgnition or Standing Pilot as it is c...

Страница 8: ...WHITE GREEN Lights ON OFF CONTROL MAIN Power 120VAC 60 Hz 6 Amps SPARK SENSOR RED BLACK BATTERY PACK MAIN ON OFF SWITCH YELLOW GREEN PILOT R ORANGE GREEN BLACK BROWN YELLOW ORANGE 6 10 6 OPTIONAL CPI IPI SWITCH WHITE LED Lights LED1 Red LED LED2 Amber LED SW1 LED o tro e r LED power s pp y white white white BLACK WHITE VARIABLE SPEED COMFORT FANS Multicolored LED Lights Fan Kit only available in S...

Страница 9: ...place instructions 10 Loop Pilot wires from behind control board drawer to the front Plug into X2 and X3 8 Place Fan wire on leftside firebox floor with adhesive wire pad For fan Install instructions see Optional fan kit Install Replace instructions 11 Valve wires are plugged into the valve in the Green Red and yellow ports respectively Figure 24 e On Off switch through drawer Figure 24 i LED wire...

Страница 10: ...ting screws into the valve body Use a standard screwdriver or T20 Torx bit and tighten to the screws with a fixing torque of 251b in 5 IN THE EVENT THAT THE THREADS OF THE VALVE ARE STRIPPED OR DAMAGED REPLACE THE VALVE 7 Install the enclosed identification label G to the valve body where it can be easily seen 8 Make STEPPER MOTOR and valve electrical connections apply gas to system and relight ap...

Страница 11: ...XG2021 11 Notes ...

Страница 12: ...XT0016 Installation Maintenance Manual PROFLAME 2 UPGRADE KIT RX 200 NG LP RX 300 NG LP ...

Отзывы: