XT0016

2

General

This upgrade kit shall be installed by a qualified service agency in 

accordance with the manufacturer's instructions and all applicable 

codes and requirements of the authority having jurisdiction. If the 

information in these instructions are not followed exactly, a fire, 
explosion or production of carbon monoxide may result causing 

property damage, personal injury or loss of life. The qualified service 

agency is responsible for the proper installation of this kit. The 

installation is not proper and complete until the operation of the 

converted appliance is checked as specified in the manufacturer's 

instructions supplied with this kit.

This upgrade kit contains the necessary components for field upgrade 

of an approved Montigo fireplace from Proflame 2 basic control 

system to Full Load with remote.

The installation of this unit must also conform with local codes or, in 

the absence of local codes, with the American National Fuel Gas Code, 

ANSI Z223.1, or the Canadian Installation Code, CAN / CGA B149.

WARNING

GENERAL INFORMATION

Note

Upon successful installation of 

this  upgrade  kit,  the  following 

features  are  available  for  the 

user:
1. Thermostatic  and  smart 

thermostatic  control  of  the 

fireplace

2. M a i n   b u r n e r   f l a m e 

modulation (6 levels)

3. Choice  of  Standing  or 

Intermittent pilot (CPI switch 

or jumper required)

4. Comfort fan speed modulation 

(Remote Fan Kit RFK3002R or 

RFK3004R required)

5. Battery backup for the main 

burner during power outage

Before You Begin

Ensure  that  the  power  supply 

has  been  turned  off  at  the 

breaker or fuse before beginning 

the installation. 

Shut off the gas supply at the 

shut-off valve, and ensure that 

the main burner and pilot light 

have  been  turned  off  and  the 

fireplace  has  been  cooled  off 

for  at  least  two  hours  before 

installation.

Tools Required

•  T20 Torx bit
•  Impact gun / Drill
•  1/4 " Nut driver bit

Contents

A. Disconnect Control Module and Harness: .........................................3
B. Stepper Motor Installation: ..................................................................3
C. Control Module Installation: ................................................................4
D. Main ON/OFF Switch Installation: .......................................................5
E. Battery Holder Installation: ..................................................................5
F. Operation with Backup Battery: ...........................................................6
G. Operation with MAIN Power: ...............................................................6
H. CPI / IPI Jumper Cable Installation ......................................................7

KIT #

Contents

RX200NG
RX300NG

Control Module, Remote Control, Stepper Motor-NG,
Manual Override switch with harness and bracket,
backup battery pack, Proflame 2 operations manual,
hardware and batteries.

RX200LP
RX300LP

Control Module, Remote Control, Stepper Motor-LP,
Manual Override switch with harness and bracket,
backup battery pack, Proflame 2 operations manual,
hardware and batteries.

Note: 

You may remove the front cover (

See Figure 2

), or the 

burner assembly to access the control module and wiring. If 

removed, please ensure it is re-installed properly and all gas 

connections are leak tested.

Remote Control

Control Module

Battery  

Pack

Manual override 

switch with harness 

and bracket

Stepper 

Motor-NG 

or LP

Proflame 2 

 

Operations Manual

Figure 1 

Contents of Proflame 2 Upgrade Kit

Hardware and 

batteries

Figure 2 

Fireplace front cover

Содержание Proflame 2 RX 300 LP

Страница 1: ...Load with Remote THIS KIT IS FOR USE WITH THE FOLLOWING MODELS RX200 B34DT 2 F B34 TOP VENT ELECTRONIC IGNITION IPI B34DR 2 F B34 REAR VENT ELECTRONIC IGNITION IPI B38DT 2 F B38 TOP VENT ELECTRONIC IGNITION IPI B38DR 2 F B38 REAR VENT ELECTRONIC IGNITION IPI PL38DFN F PL38 ELECTRONIC IGNITION IPI PL38DFL F PL38 ELECTRONIC IGNITION IPI PL42DFN F PL42 ELECTRONIC IGNITION IPI PL42DFL F PL42 ELECTRONI...

Страница 2: ...it RFK3002R or RFK3004R required 5 Battery backup for the main burner during power outage Before You Begin Ensure that the power supply has been turned off at the breakerorfusebeforebeginning the installation Shut off the gas supply at the shut off valve and ensure that the main burner and pilot light have been turned off and the fireplace has been cooled off for at least two hours before installa...

Страница 3: ... and Sensor Wire from connectors X2 and X3 of the control module 3 Disconnect the wall switch harness from X4 Control Module and discard 4 Remove the Valve Harness from X5 of the control module 5 Remove the connector from X1 of the control module 6 Remove the control module from firebox compartment and discard Note module is attached by velcro strips Figure 3 Powercord in PPO box Figure 4 Control ...

Страница 4: ...alve body Use a torque screw driver with Torx T20 bit to tighten the two screws to a torque setting of 25 lb in 5 5 Install the enclosed identification label to the valve body Figure 12 G Figure 11 Stepper Motor Installations Figure 12 Label Installation Figure 13 Identification Label NG Figure 14 Identification Label LP Figure 15 New Control Module Figure 16 X1 plug on control module 3 Connect th...

Страница 5: ...N OFF sticker supplied to the switch bracket E Battery Holder Installation 1 Secure the battery holder to the fireplace floor using the supplied velcro strips See Figure 22 Note The velcro strips act as an electrical isolation do not attach the battery holder to any metal part without using the velcro strips or the control module will be damaged 2 Connect the red and black wires from the battery h...

Страница 6: ...and ensure no leak 5 Turn the fireplace ON and modulate the flame using the remote control and ensure proper operation see Proflame 2 Operation and Maintenance Manual XG0677 Blue Back lit LCD display On Off Key Thermostat Key Up Down Arrow Key Mode Key Figure 24 Proflame Remote Control G Operation with MAIN Power 1 Remove the four batteries from the battery holder 2 Plug the Control Module Power c...

Страница 7: ...ially recovered asheatintothebuilding soitdoesnotwasteasmuchenergyasrunning a pilot in the off season A connector is supplied with this unit that can be plugged into the wire harness connected to the controller This Jumper Cable gives the Remote Control the ability to operate the CPI IPI switch and set the unittooperateineithercondition CPImeans ContinuousPilotIgnition or Standing Pilot as it is c...

Страница 8: ...WHITE GREEN Lights ON OFF CONTROL MAIN Power 120VAC 60 Hz 6 Amps SPARK SENSOR RED BLACK BATTERY PACK MAIN ON OFF SWITCH YELLOW GREEN PILOT R ORANGE GREEN BLACK BROWN YELLOW ORANGE 6 10 6 OPTIONAL CPI IPI SWITCH WHITE LED Lights LED1 Red LED LED2 Amber LED SW1 LED o tro e r LED power s pp y white white white BLACK WHITE VARIABLE SPEED COMFORT FANS Multicolored LED Lights Fan Kit only available in S...

Страница 9: ...place instructions 10 Loop Pilot wires from behind control board drawer to the front Plug into X2 and X3 8 Place Fan wire on leftside firebox floor with adhesive wire pad For fan Install instructions see Optional fan kit Install Replace instructions 11 Valve wires are plugged into the valve in the Green Red and yellow ports respectively Figure 24 e On Off switch through drawer Figure 24 i LED wire...

Страница 10: ...ting screws into the valve body Use a standard screwdriver or T20 Torx bit and tighten to the screws with a fixing torque of 251b in 5 IN THE EVENT THAT THE THREADS OF THE VALVE ARE STRIPPED OR DAMAGED REPLACE THE VALVE 7 Install the enclosed identification label G to the valve body where it can be easily seen 8 Make STEPPER MOTOR and valve electrical connections apply gas to system and relight ap...

Страница 11: ...XG2021 11 Notes ...

Страница 12: ...XT0016 Installation Maintenance Manual PROFLAME 2 UPGRADE KIT RX 200 NG LP RX 300 NG LP ...

Отзывы: