background image

 
H38DF PRC 
HL38DF PRC 
HP38DF PRC
 
Panorama 
Indoor 
Residential
Gas Fireplace

®

C

US

Read and understand this manual. Improper installation, adjustment, alteration, 

service or maintenance can cause serious injury, property damage or even death. 

For assistance or additional information consult a qualified installer, service 

agency or the  gas supplier.

DANGER

Installation & Maintenance Manual

Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of 

this or any other gas  burning appliance.  A fire or explosion my occur causing serious 

injury, property damage or even death.

WARNING

Installer: Leave this manual with the appliance. Do not remove. 

Consumer: Retain this manual for maintenance and future reference. Do not Discard.

NOTICE

IF YOU SMELL GAS

  Do not try to light any appliance.

  Do not touch any electrical switch;  do not use any phone in your building.

  Immediately call your gas supplier from a neighbor's phone. Follow the gas 

supplier's instructions.

  If you cannot reach your gas supplier, call the fire department.

DANGER

Irritant

Cutting

Watch your step

Slippery floor

High temperatures

Glass hazard

Danger of suffocation

High voltage 

Toxic 

Flammable materials

Corrosive

Fork lift trucks 

Danger overhead crane

Explosion risk

Oxidising

Danger of death 

Biohazard

Laser Radiation

Danger of entrapment

Hot surface

General Warning

Blank

Gas bottles

Watch for 

falling objects

Electricity

Danger for cutter

Entrapment hazard

Battery hazard

Rotating parts

Low temperature

Strong magnetic field

Optical radiation

Non ionizing

 radiation

Radiation

Hazardous to the

Environment

Danger of harming 

your hands

Irritant

Cutting

Watch your step

Slippery floor

High temperatures

Glass hazard

Danger of suffocation

High voltage 

Toxic 

Flammable materials

Corrosive

Fork lift trucks 

Danger overhead crane

Explosion risk

Oxidising

Danger of death 

Biohazard

Laser Radiation

Danger of entrapment

Hot surface

General Warning

Blank

Gas bottles

Watch for 

falling objects

Electricity

Danger for cutter

Entrapment hazard

Battery hazard

Rotating parts

Low temperature

Strong magnetic field

Optical radiation

Non ionizing

 radiation

Radiation

Hazardous to the

Environment

Danger of harming 

your hands

Irritant

Cutting

Watch your step

Slippery floor

High temperatures

Glass hazard

Danger of suffocation

High voltage 

Toxic 

Flammable materials

Corrosive

Fork lift trucks 

Danger overhead crane

Explosion risk

Oxidising

Danger of death 

Biohazard

Laser Radiation

Danger of entrapment

Hot surface

General Warning

Blank

Gas bottles

Watch for 

falling objects

Electricity

Danger for cutter

Entrapment hazard

Battery hazard

Rotating parts

Low temperature

Strong magnetic field

Optical radiation

Non ionizing

 radiation

Radiation

Hazardous to the

Environment

Danger of harming 

your hands

Irritant

Cutting

Watch your step

Slippery floor

High temperatures

Glass hazard

Danger of suffocation

High voltage 

Toxic 

Flammable materials

Corrosive

Fork lift trucks 

Danger overhead crane

Explosion risk

Oxidising

Danger of death 

Biohazard

Laser Radiation

Danger of entrapment

Hot surface

General Warning

Blank

Gas bottles

Watch for 

falling objects

Electricity

Danger for cutter

Entrapment hazard

Battery hazard

Rotating parts

XG0211     

151126

 Canadian Heating Products Inc. Langley, BC  V4W 4A1   |   Montigo Del Ray Corp. Ferndale, WA  98248

Содержание H38DF PRC

Страница 1: ... Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank Gas bottles Watch fo...

Страница 2: ...LING A WALL MOUNTED DIRECT VENT 12 Section 3 3 1 VENTING LAYOUT 13 Section 3 3 2 VENTING COMPONENTS 17 Section 3 3 3 Heat Shields 18 Section 4 Wiring 19 CPI Continuous Pilot Ignition IPI Intermittent Pilot Ignition Jumper Cable Installation only available for SIT Electronic Ignition Systems 20 Section 5 Installing the Gas Line 21 Section 5 1 FUEL CONVERSION 21 Section 5 2 GAS PRESSURE 21 Section 5...

Страница 3: ...y Information See Appendix B TheMontigowarrantywillbevoidedby andMontigodisclaimsany responsibility for the following actions Modification of the fireplace and or components including Direct Vent assembly or glass doors Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult you...

Страница 4: ...es orintheabsenceoflocalcodestothecurrentversionofNaturalGas and Propane Installation Code CSA B149 Electrical Installations must conform to the local codes or in the absence of local codes to the current version of Canadian Electrical Code CSA C22 1 1 Installations in the USAmustconformtothelocalcodes or in the absence of local codes to the current version of National Fuel Gas Code ANSI Z223 1 NF...

Страница 5: ...stallation Section Rating Plate Sample LB1223 V5 0 SIT IPI with screen JUN 16 2014 Teklynx LabelView Demo LB1223 V5 1 SIT IPI with screen DEC06 2014 Teklynx LabelView Demo Figure A Rating Plate for IPI eletronic ignition Figure B Rating Plate for standing pilot SIT ...

Страница 6: ...f your fireplace The H 38PR fireplace may be installed in any location that maintains proper clearances to air conditioning ducts electrical wiring and plumbing Safety as well as efficiency of operation shouldbeconsideredwhenselectingthefireplacelocation Select a location that does not interfere with room traffic has adequate ventilationandoffersanaccessiblepathforDirectVentinstallation Top View F...

Страница 7: ...it is installed Figure 2 Framing dimensions 24 1 2 40 3 4 44 Figure 3 Combustible Framing for shelves over the fireplace Rear vent Note HP38DF CANNOT be straight run rear vented with wall termination Figure 4 Combustible Framing for shelves over the fireplace Top vent HP38DF is 59 Figure 5 Non Combustible Framing with alcove above fireplace Top Vent 11 29 Combustible Framing Header shelf 33 1 2 44...

Страница 8: ...ll H 38PR gas fireplaces are required to have the supplied standoffs installed The fireplace is supplied with two standoffs Bend and install these standoffs on top of the fireplace ensuring that the height of the standoff maintains a 8 clearance Figure 6 Installing the H 38PR standoffs Note Clearance from top of fireplace to a ceiling within the fireplace enclosure Fasten Standoffs in gutter 8 Nai...

Страница 9: ...ations to ensure the planned termination location is acceptable Once the termination location has been established refertotheappropriatesectionbelow for installation details All fireplaces shipped from the factory are Top vent SiliconeapplicationisNOTrequiredwhenjoining Montigo vent pipes and components Figure 8 Flue cover and collar removal Top Vented fireplace Figure 8a Flue cover and collar ins...

Страница 10: ...tionmustbeaminimum6 fromamechanical air inlet Foramoredetaileddiagramofallowedterminationlocations see Appendix A A maximum of two offsets each offset is made up of 2 90 bends may be made for vertical vent runs Firestops must be installed as required by National local codes Ensure all horizontal runs are supported with a minimum of 3 supports per 10 of venting Install all roof flashing and storm c...

Страница 11: ...tion Note Images are shown without screens for clarity purposes However your fireplace should not be operated without proper installation of screens Figure 9c Rear vent Roof mounted venting 1 90 bend Support ring Support plate 32 M a x PVTK1 Termination 12 Max Storm Collar ...

Страница 12: ...ure 10b Installing a PTO termination with the BSR frame 3 Installation of termination frame at time of framing in Masonry Terminations with a BSR frame allow the installation of the frame in masonry prior to the installation of the termination 1 Frame the BSR opening to 12 x 12 2 Secure the BSR Frame to the exterior sheathing of the structure 1 Frame the MOSR opening to 12 x 12 2 Fasten the MOSR f...

Страница 13: ... venting graphs see Figure 12 or 12a Figure 12a H38PR or HL38PR Top Vented wall mounted installation with one 90 bend The vent run must comply with Venting Graph for Top vent wall mounted terminations Figure 12 42 46 A C B If your installation does not fall with in the venting graph parameters please contact a local Montigo dealer for Power Venting options Unacceptable vent run within shaded area ...

Страница 14: ... Retracted Multi elbow installation See Venting Graph for Top vent wall mounted terminations Figure 12 or 12a Solid Section Flex Section Hearth Heat Shield Termination Exterior Wall 150 max Figure13 HP38PR TopVentVentingGraphforwallmountedterminations Heat Shield Termination Hearth Exterior Wall 59 Min 18 Max Flex or Rigid Section Figure 13a HP38PR Top Vented wall mounted installation with one 90 ...

Страница 15: ...erticaldimensionfromthehearthis66 andthehorizontal run to the wall flange of the vent termination is 84 this would NOT be an acceptable installation Example C Unacceptable Installation If the vertical dimension from the floor of the fireplace is 72 andthehorizontalruntothewallflangeoftheventtermination is 144 this would NOT be an acceptable installation Figure 15 H38PR or HL38PR Straight run Rear ...

Страница 16: ...r Vented wall mounted Multi elbow termination installation The vent run must comply with the Venting Graph for Rear vent wall mounted terminations Figure 14a Figure 15a H38PR or HL38PR Rear Vented wall mounted Multi elbow termination installation The vent run must comply with the Venting Graph for Rear vent wall mounted terminations Figure 14 46 Max 59 Min 12 Max 26 Min 33 Flex or Rigid Section 42...

Страница 17: ...rproofing Consultant forareviewof ALLpenetrationsthrough exterior walls or the roof Montigo recommends the use of a flex section for the final pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement Firestops must be installed as required by National local codes Montigo recommends that all exterior corners and joints be sealedwithexteriorcau...

Страница 18: ...tion Drywall sheetrock RHS101 Heat Shield inner Section RHS101 Heat Shield Outer Section Installing a Wall Mounted RHS101 Heat shield TheRHS101HeatshieldMUSTbeusedwheretheRHS8Termination Figure 16 and 16a CANNOT be used Use the RHS101 where any of the dimensions are within the parameters shown figure 16a ToinstalltheRHS101 SlidetheInnerSectionovertheventpipethat will connect to the fireplace Then ...

Страница 19: ...F HL38DFPRCL F HP38DFPRCL F Installing the remote On Off Wall Switch The SIT Nova 820 gas valve may be connected to a wall switch Do NOT connect any external power to the remote switch The valve will generate its own power on a millivolt circuit or will draw its power from an AC Connection inside the fireplace depending on the model of the unit Use only low voltage wire and DO NOT connect any exte...

Страница 20: ...successfully The fireplace will then attempt to re light a second or third time depending on prevailing temperatures or altitude When in CPI mode the pilot also keeps the system warm During a cold start condensation will normally form on the inner glass surface of the door This condensation will quickly dry however the condensation tends to run down the glass and cause some streaking CPI mode help...

Страница 21: ...h unless allowable within local regulations Connect incoming gas line to the 1 2 or 3 8 gas inlet port Purge all air out of gas line Check appliance connection valve and valve train under normal operating pressure with a commercially available leak check solution DO NOT USE A FLAME OF ANY KIND TO TEST FOR LEAKS Section 5 1 FUEL CONVERSION Section 5 2 GAS PRESSURE Section 5 3 GAS CONNECTION Optimum...

Страница 22: ... remember the following THE OPENING MUST NOT BE OBSTRUCTED IN ANY WAY to do so restricts the air supplyforthecontrolcompartmentsandheatexchanger it also prevents access for servicing controls The face of the fireplace may be painted to match the room decor provided you use a heat resistant paint Decorative facing must not extend past the fireplace opening at all because it will interfere with the ...

Страница 23: ...ns Hold the screens at an angle away from the fireplace andlocatetheScreenBottomTabsatthelowercorners of the screen Place the screen into the Screen Tab Receptacles in the lower section of the fireplace Make sure the tabs and screens are lowered all the way down into the Screen Tab Receptacles on the fireplace Then push each Upper Screen Stud on the top corners of the screen into the Upper Screen ...

Страница 24: ... 5 Ensure the tool is firmly in the lower end of the slot as shown Then pull toward you Caution hold the tool securely 3 Step 6 Pull hard if necessary to release the spring ten sion Caution The latch springs back with force hold the tool securely 4 Step 7 Remove the tool from the latch slot Ensure the latches are hanging freely the hook end is released from the bottom of the door Repeat all 4 step...

Страница 25: ...ling the Door Step 8 GrasptheDooroneitherside usuallymidwayandliftupward liftthedoorcarefullyupandawayfromthefrontofthefireplace See Figures 26g Place the Door aside in a safe place whilemaintenanceand orcleaningisbeingperformed Figure 26g Removing and installing the glass door Removing the Door WARNING When installing the fireplace gas lines fittings accesso ries or any other objects cannot imped...

Страница 26: ...erialissuppliedintwopackages Spreadthematerial evenly around the burner tray or pile around burner holes for a realistic effect Figure 27c Log Installation Place Logs C on top of Logs A Indentations on top of Logs A Figure 27b Place Logs B as shown in front of Right hand A and behind Left hand B Log A Log B Log C Log A Log C Figure 27d Completed Installation Figure 27 Empty firebox showing the Lef...

Страница 27: ...perly excessive sooting will result Installing the Ember Material Figure 28a Place Log A and B in the grate on either side of the burner Log A Log B Log D Log C Figure 28b Place Log C and D diagonally across Logs A and B Figure 28c Place Log E diagonally across Log C Ensure that log E does not touch the grate Log E Figure 28d Place log F and Log G at opposite sides of unit onto log slot Log F Figu...

Страница 28: ...Natural Gas and Propane Fireplaces The HL38PR fireplace is supplied with firestones Remove the Door as shown on page 24 Follow these instructions to ensure all parts are removed or replaced as required Once the glass door is removed place the firestones randomly across the pan as described in Figure 29 to 29a Figure 29 Completed firestone installation Second Gen burner shown Note DO NOT place ANY ...

Страница 29: ...gnition phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the Fire De partment C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempt to repair may result in a fire or explosion D Do not use this appliance if any part h...

Страница 30: ...n fireplace ON using wall switch or remote control 7 If the Fireplace does not light the System will cycle through two trials one minute audible clicking thirty seconds of silence and then another one minute of audible clicking If the system locks out due to inadequate gas flow refer to Troubleshooting in instruction guide 8 After completion of the information in the Troubleshooting section Repeat...

Страница 31: ...w B in the safety information above on this label If you don t smell gas go to the next step 5 Turn switch on the gas control to ON NOTE This unit is equipped with an ignition system that lights the pilot burner automatically Do not attempt to light the pilot by hand 6 Turn on wall switch 7 Replace the lower Horizontal access panel 8 If the fireplace does not operate follow the instructions To Tur...

Страница 32: ...lay A Mode Key is provided to index between the features and a Thermostat Key is used to turn On Off or index through Thermostat functions see Figure 30 Additionally a Key Lock feature is provided The Proflame 2 System consists of the following elements 1 Pilot Assembly 2 Proflame Gas Valve 3 Proflame 2 Control Module 4 Wiring Harness 5 Variable Speed fans 6 Variable Accent Lights 7 Proflame 2 rem...

Страница 33: ...ame time Look at the LCD screen on the Remote Control to verify that a C or F is visible to the right of the Room Temperature display Turn On the Fireplace With the system Off turn the master override switch to on and press the On Off Key on the Remote Control The Remote Control display will show some other active Icons on the screen At the same time the Control Module will activate the fireplace ...

Страница 34: ...CD display on the remote control will change to show that the room thermostat is On and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Transmitter Smart Thermostat Remote Control Operation The Smart Thermostat function adjusts the flame height in accordance to the difference ...

Страница 35: ...tivate this function use the Mode Key see Figure 30 to index to the accent light icon see Figure 30m Pressing the Up Arrow Key will turn the light on at the lowest setting Continue pressing up to get brighter Pressing the Down Arrow Key will turn the lights down until you get to the off position A single beep will confirm the reception of the command Disabling Thermostat Some jurisdictions and bed...

Страница 36: ...Mode and Up Keys at the same time see Figure 30o To de activate this function press the Mode and Up Keys at the same time Remote Control When the Remote Control batteries are low a Battery Icon will appear on the LCD display of the Remote Control see Figure 30p before all battery power is lost When the batteries are replaced this icon will disappear Control Module When the back up batteries are lo...

Страница 37: ...left on the glass This is a normal condition and is the result of burning of protective coatings on new metal Glass must be cleaned periodically to remove any film which is a normal by product of combustion which may be visible Film can easily be removed by removing the door as shown on Page 24 Handle the door carefully and clean it with non abrasive glass cleaners One of the most effective produc...

Страница 38: ...urner will not Light 1 Check and verify all wiring connections as per the wiring diagram 2 Verify the inlet and Manifold Pressurearewithinacceptablelimits Pilot lights but Main burner will not Light and igniter continues to spark 1 CheckthePilotFlameSensorRod and clean with steel wool or similar 2 Check the Pilot hood and clean with steel wool if dirty 3 Adjust pilot flame using the pilot adjustme...

Страница 39: ...Control Module RGC3061 Proflame Transmitter RGC3063 Replacement Screen RSCH38PRC1 RSCH38CL2 RSCH38CR2 RDTH38PR02 RDTH38PR01 RDTH38PR02 DWG N Finish MATERIA DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 32 TWO PLACE DECIMAL 015 THREE PLACE DECIMAL 005 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE Revision Date Drawn by DATE NAME THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPE...

Страница 40: ...or appliance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved driveway located on public property 7 feet 7 feet P clearance under veranda porch deck or balcony 22 inches to combustibles 16 inches to non combustibles 22 inches to combustibles 16 inches to non combustibles Q clearance above roof 2 f...

Страница 41: ...ppliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive...

Страница 42: ...m height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not app...

Страница 43: ...H 38DF PRC Panorama Indoor Gas Fireplace Page 43 XG0211 151126 Notes ...

Страница 44: ...XG0211 151126 H38DF PRC Panorama Gas Fireplace ...

Отзывы: