16
Installation
XG0146 - 180405
Figure 10.
Corner Installation
Figure 10.b
Corner Installation Flex
45° Corner Installation 4''/7''
Attach an EEL-45 (45° elbow) directly onto the flue collar. Cut the MXT-
20 to suit, and attach it to the EEL-45. Slide the fireplace into position
and attach to the termination.
45° or less Corner Installation 4''/7''
Use an MTO-4 termination and an MFL-1 or MFL-2 (12" or 24" compressed
length) and a frame, if appropriate. Flex may be turned to obtain desired
degree of angle required but must not exceed 45°.
NOTE:
Through the wall venting kits are also available for both the
Straight and the Corner Installation. The Kit includes a heat shield, a
MFL-12 (f/f) flexible pipe, and a termination with or without a mounting
frame.
Corner Installation is available for
NATURAL GAS UNITS ONLY
NOTICE
Termination
RHS 100
Heat Sheild
EEL- 45 Elbow
MXT-20
Flue Collar
Termination
RHS 100
Heat Sheild
Flex Section
Flue Collar