10
Installation
XG0146 - 180405
Figure 5. Flue cover and collar removal, Top Vented fireplace.
Figure 5.b Flue cover and collar installation, Rear Vented fireplace.
Flue Gasket
Flue Cover Plate
8” Outer Flue Collar
5” Inner Flue Collar
Section 3: Venting
Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that it is the
highest point in the venting assembly. It should also be selected such
that it provides the shortest vent run possible. Should it be impossible
to ensure that the termination is the highest point or to meet the
venting guidelines laid out below please contact your Montigo dealer
to discuss power venting options.
Notes For Planning Venting:
• Venting can originate from the unit through the top or through the rear
• Venting can terminate through the roof or through an exterior wall.
• Refer to Appendix A - Termination Locations to ensure the planned
termination location is acceptable.
• Once the termination location has been established, refer to the
appropriate section below for installation details
•
All fireplaces shipped from the factory are top vent.
• Silicone
application is
NOT
required when joining Montigo vent
pipes and components.
Section 3-1: Converting to Rear Vent
Use the following instructions to convert a unit for Rear Vent use:
•
Remove the Rear flue cover and gasket (4" and 7") on the flue outlet,
as shown
•
Next, Remove the Top flue collar's (4" and 7") on the flue outlet, as
shown
•
Install the (removed) Rear flue cover and gasket material, to the Top
vent outlet. Fasten the cover with included hardware, as illustrated
• Install the (4" and 7") collars to the rear vent outlet using the included
hardware, as illustrated
5” Inner Flue Collar
8” Outer Flue Collar
Flue Gasket
Flue Cover Plate
Flue Cover Plate
Flue Cover Plate
Flue Gasket
Flue Gasket
7'' Outer Flue Collar
7'' Outer Flue Collar
4'' Outer Flue Collar
4'' Outer Flue Collar
Under no circumstances can Montigo flex venting be cut to
accommodate an installation. Use an alternative length to complete
your vent run.
NOTICE