![Montavlo X-3000ce-UW Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/montavlo/x-3000ce-uw/x-3000ce-uw_installation-and-operating-instructions-manual_1829726007.webp)
1/3/02 7
General Function and Standard Operation
Cabinet Version
1. Manual setpoint
Sets controller output at a constant level when the controller is in manual mode.
(Manual setpoint on a 0 to 100% scale produces 0 to 100% output.)
2. Auto setpoint
In auto mode, the controller automatically regulates output so that actual tension
reaches the tension setpoint (appears on a scale of 0 to 100% on the meter).
3. Actual tension
Displays actual tension on a scale of 0 to 100%.
4. Controller output meter
Displays controller/regulator output on a scale of 0 to 100%.
5. Manual / Auto switch
Switches between manual and auto mode.
6. Tension on/off switch
Turns tension on and off. Output is zero when off.
7. Green power LED
Indicates that power is on.
IL030.dsf
OPTION:
-Cal. low/high
OUTPUT
50
20
80
100%
0
50
20
80
100%
0
MANUAL/
AUTO
TENSIO N
OFF/ON
AUTO
MANUAL
50
20
80
100%
0
3
4
5
6
1
2
OPTION:
-Splice level
7