background image

Two Way Car Alarm System  MONGOOSE EMS 1.7R

11

ENGLISH

Silent Disarm

Pressing button 1 immediately before button 2 is pressed will disarm the alarm system without

beeping the siren unit. All other features including the indicator flashes will remain the same.
Note: If the alarm is giving the driver a warning such four flash warning that the alarm has been
triggered, the alarm system will beep the siren even if it is overridden by the remote or the
software switch. Fault warnings take priority over silent disarming.

Sensor Override Mode

Press button 1 twice within 3 seconds while arming will cause the alarm to arm with perimeter

protection only. All internal motion sensors will be overridden.

Sensor’s Warning Zone Override Mode

Press button 2 within 3 seconds of button 1 pressed while arming will cause the alarm to arm

without warning zones of the shock sensor and optional sensor being enabled.

To arm the alarm systems without the sensor or sensor’s warning zone being enabled without

beeping the siren unit sequentially press buttons 211 or 212 respectively.

NOTE:

 If you use the Silent Arming/Disarming modes, the LCD transceiver will confirm

the receipt of a response from the alarm system also without audible signals.

Arm with Engine Running

Arming the Alarm with Engine Running with  Ignition/ACC Support

Ask your dealer to make necessary connection for the ignition/ACC support to be available.

NOTE: 

A time delay for the activation of the Arm with Engine Running feature is included

to prevent accidental operation while the car is moving. The full sequence is as following:

i) Keep the Ignition ON with key.
ii) Press button S followed by button 2 to switch on the Ignition/ACC support. One siren beep

and one indicator flash will confirm the ignition/ACC support is turned on.

iii) Remove the key.
iv) Open a Door.
v) Press button 2. The siren will beep once and the indicators will flash once.
vi) Close the Door within 10 seconds of button 2 being pressed.
vii) 10second timer period start.
viii) Press button 1 within 10 seconds of closing the door.

ix) Arm with engine running is activated.

The LCD transceiver will display the alarm system is armed with engine running.

Руководство  пользователя

EMS 1.7R

42

младшего разряда PIN кода нажмите кнопку аварийного отключения необходимое чис
ло раз и подождите несколько секунд не выключая зажигания. Если код введен пра
вильно пассивный иммобилайзер и Anti HIjack отключатся, при этом дважды мигнут
сигнальные фонари. При выключенном режиме Anti Hijack отключить иммобилайзер
вводом младшего разряда двузначного PIN кода нельзя.

Если при попытке отключить иммобилайзер, нажата не та комбинация кнопок, кото

рая запрограммирована для его отключения, немедленно включится тревога, отключить
которую можно следующими способами:

1. Нажать нужную комбинацию кнопок брелока.
2. Ввести полный PIN код (однозначный или двузначный).
3. Выключить зажигание и нажать любую кнопку пульта.
В первом и втором случае тревога и блокировка двигателя отключатся одновременно.

В третьем случае тревога отключится, но блокировка двигателя сохранится до нажатия
нужной комбинации кнопок или ввода правильного PIN кода.

ВНИМАНИЕ!

 Если при одновременно включенных пассивном иммобилайзере и Anti

Hijack дважды нажата неправильная комбинация кнопок пульта, дальнейший прием
команд пульта управления будет заблокирован системой на две минуты или до ввода
правильного PIN кода, светодиод при этом будет мигать двойными вспышками. Отклю
чение иммобилайзера и Anti Hijack вводом младшего разряда или полного PIN кода по
прежнему возможно. Однако, если дважды введен неправильный PIN код, включится
двух минутная блокировка ввода PIN кода.

Включив программно режим иммобилайзера, 

помните

, что:

 при включенном зажигании и стоящем на охране иммобилайзере система не будет

выполнять никакие команды брелока до снятия иммобилайзера с охраны;

 после снятия сигнализации с охраны блокировка двигателя сохранится, для ее от

ключения нажмите комбинацию кнопок брелока, отключающую иммобилайзер,
или введите PIN код.

Включение тревоги в режиме пассивного иммобилайзера (второй уровень защиты от не%

санкционированного снятия с охраны ASL

TM

)

Если система не была поставлена на охрану после включения пассивного иммоби

лайзера, согласно процедуре 

DAPS

TM

, тревога включится только в случае, если нажата

неправильная комбинация кнопок при его отключении.

С  помощью функции 

ASL

TM

 можно задать один из 4 режимов процедуры 

DAPS

TM

после снятия с охраны:

1. Тревога включиться только при нажатии неправильной комбинации кнопок. (Завод

ская установка)

2. Тревога включится, если иммобилайзер не отключен в течение 15 секунд после

открытия двери.

3. Тревога включится, если иммобилайзер не отключен в течение 30 секунд после

открытия двери.

4. Тревога включится, если иммобилайзер не отключен в течение 60 секунд после

открытия двери.

Примечание: При первом включении иммобилайзера после переключения автомо

бильного аккумулятора тревога включится в соответствии с установками функций ASL

TM

,

даже если система не была поставлена на охрану.

Содержание EMS 1.7R

Страница 1: ...nd a pager system will warn you about any intrusion into your car Enhanced anti theft facilities are ensured by a powerful built in blocking relay and an additional universal output available to conne...

Страница 2: ...ng a command the transmitting indicator will be displayed on the LCD panel See the Command Summary for more details Button 1 Button 2 Button 3 Button S Button M Transceiver RF Range Conditions Pager R...

Страница 3: ...gered 24 Hour Clock Doors Locked Doors Unlocked Power Save Mode Engine Running Door Open Hood Open Trunk Open Low Battery Warning Ignition ON Transmitting a Command ValetMode PagerTest Button Lock Par...

Страница 4: ...to the current time display however the last value of the parking time will remain in the transceiver memory until the next arming You can check time of parking with pressing button S As soon as you a...

Страница 5: ...ton M and Button 3 together This will cause the alarm system to respond by sending the latest status information to the Transceiver so it can be immediately displayed on the LCD panel Power Save Mode...

Страница 6: ...isarmed Unlock Ignition ON Passive Immobiliser Disarmed Panic 3s Ignition OFF Car Finder Armed or Valet Mode with the ignition switched OFF Trunk Release 3s Anystatus Latch Output 2nd 1st 3 minute Tur...

Страница 7: ...le on the 2 Way Transceiver which armed the alarm system If another valid 2 way Transceiver is in range of the vehicle when the alarm system is triggered that Transceiver will not receive the pager si...

Страница 8: ...interior light in your car includes a delay when the door is closed turn this function on there will be no additional warning beeps on arming the alarm system with the interior light left switched on...

Страница 9: ...ming is set with programming Is flashing Melody 6 Reconnection of the Power Supply while Light Indicators are Melody 5 1time per 5 seconds Armed flashing Passive Immobiliser Trigger Period is Current...

Страница 10: ...of the first pressing NOTE 2 Stage Unlock is only available while disarming with ignition turned OFF 2 Stage Disarm To disarm the alarm system normally press the disarm button If the alarm system has...

Страница 11: ...ively NOTE If you use the Silent Arming Disarming modes the LCD transceiver will confirm the receipt of a response from the alarm system also without audible signals Arm with Engine Running Arming the...

Страница 12: ...ou have turned on the Anti Hi jack function then once you open a door with the ignition on firstly turn the Anti Hi Jack off see the Anti Hi Jack section for details and then fulfil the enter Arm with...

Страница 13: ...ith turbo timer but the engine will not be blocked until the ignition is switched off However if you set the Immobiliser Trigger Period with programming the alarm will be triggered in set time period...

Страница 14: ...second arming period Ignition Safety Door Lock Unlock This feature can be selected using programming 5 seconds after the ignition is turned on the doors will lock for passive safety and will automati...

Страница 15: ...itter as normal All features including auxiliary output panic mode car finder and arming of the alarm system will function normally If the ignition is switched on then the transmitter cannot be used t...

Страница 16: ...m and the passive immobiliser will disarm If option i is used then the alarm system will stop sounding and the alarm will disarm but the passive immobiliser will remain engaged You must still press th...

Страница 17: ...first time after reconnection of the car battery Anti Hi Jack NOTE The Hi jacking mode will only be available if you set a 2 digit Pin code The EMS 1 7R alarm system includes an Anti Hi Jacking Car J...

Страница 18: ...e siren will continue to sound and the immobiliser depending on the setting of the Installer s Function 1 5 will either remain disengaged until the ignition is switched off or operate in accordance wi...

Страница 19: ...er disarm command will be completely ignored until the Anti Hi jack has been exited Blocking in Trouble Simulation While in the Anti Hi jack This feature can be selected using programming The system i...

Страница 20: ...ctivated as soon as the alarm system is triggered and also as soon as a door is opened under armed condition when Entry Alarm Delay is turned on Self Diagnostics Functions Intrusion Warning If the doo...

Страница 21: ...leted Pager Test Once button 3 is pressed with the alarm system armed or armed with the engine running a Pager Test feature for current armed period will be included 5 minutes after you press button 3...

Страница 22: ...n the Latch Output with pressing button 2 immediately after button S the input will remain active until either disarming or pressing button 2 immediately after button S once again If you turn on the T...

Страница 23: ...ntil the indicator icon on the LCD screen is flashing two times to confirm the main unit code has been programmed to the transceiver otherwise the pager function will not work 8 To exit the Code Learn...

Страница 24: ...rated Car Jacking Mode ON OFF OFF ON OFF 2 7 Pre warn sensor zone triggered indication on the transceiver ON ON OFF 3 1 PIN Access 1 9 button 2 only or 1 Press 1 9 times to set Press 1 9 times to set...

Страница 25: ...MONGOOSE EMS 1 7R 25 Mongoose EMS 1 7R Mongoose EMS 1 7R Mongoose EMS 1 7R Anti Hi Jack KeeLoqTM Valet 8 Mongoose EMS 1 7R Mongoose EMS 1 7R EMS 1 7R 28 350 400 250 300 700 900 400 450 1500 800...

Страница 26: ...EMS 1 7R 26 3 5 Mongoose EMS 1 7R Mongoose EMS 1 7R MAwKTM Mongoose EMS 1 7R Mongoose EMS 1 7R Mongoose EMS 1 7R MONGOOSE EMS 1 7R 27 1 5 24 LR03 AAA 1 6 1 2 3 S M...

Отзывы: