NOTE:

 If the button 1 is pressed outside the 10 second window after the door is closed or the

door has been closed outside 10 seconds of button 2 being pressed, operation the arm with engine
running feature will not activate.

When armed with engine running the alarm system will arm with:

 Perimeter Protection only
 Arm Output will be remain off
 The Comfort Output will activate for 20 seconds
 Internal Immobiliser relay will be disarmed
 Sensor sockets will be disabled.

If the alarm system is armed with engine running the alarm system will exit armed with

engine running mode if:

1. 

Perimeter protection trigger 

– The alarm system will change state to the fully armed

condition and then enter the triggered mode and the engine will be blocked.

2. 

User Disarms armed with engine running

 – If you press button 1 immediately before

(within 3 seconds) of pressing button 2 with the ignition switched on, the alarm system
will disarm and the Ignition Support will be switched off.

3. If the alarm system remains in the armed with engine running mode for 10 minutes the

alarm system will automatically arm the Immobiliser. Once the Immobiliser is in
Permanent Block mode the alarm system will enter the fully armed condition with both
perimeter protection and all sensors enabled.

NOTE:

1. If you have turned on the Anti Hijack function, then once you open a door with the

ignition on firstly turn the Anti HiJack off (see the Anti HiJack section for details) and
then fulfil the enter Arm with Engine Running procedure.

    Remember that switching the Anti Hijack off with a door open will cancel the Anti Hijack

activation until the next switching the ignition on.

2. If you have turned on the Passive Immobiliser, the engine will be blocked as soon as you

disarm the alarm system from armed with engine running. (See the Passive Immobiliser
section for details of the passive immobiliser disarming procedure).

Turbo Timer

If you turn on the Turbo Timer mode, the ignition support will be switched on for a duration

of either 3minutes or 5minutes depending upon which transceiver button is used to turn on the
feature. In Turbo Timer mode you can arm the alarm system as normal. This will allow you to
keep the engine running without the key for cooling purpose.

If button 3 is pressed within 3seconds of button S being pressed when the alarm system is in

the fully disarmed condition, then the turbo timer output will switch on for 3minutes. If however,
button 4 is pressed within 3seconds of button S being pressed when the alarm system is in the
fully disarmed condition then the turbo timer output will switch on for 5minutes.

Автомобильная охранная система “MONGOOSE” Модель EMS 1.7R

41

РУССКИЙ

Дистанционное управление центральным замком.

При включенном зажигании замки дверей автомобиля могут быть в любой момент

заперты или открыты нажатием на брелоке кнопок 1 или 2 соответственно.

Если Вы принудительно открыли замки всех дверей, нажав при включенном зажи

гании кнопку 2 дважды, то после этого при выключении зажигания будут отпираться
замки всех дверей, несмотря на то, что при снятии с охраны был открыт только замок
водительской двери. Режим отпирания дверей при выключении зажигания сохраняется
до следующего снятия с охраны.

Режим пассивного иммобилайзера.

Режим включается и выключается программированием.

Если режим программно включен, то сразу после открытия двери при выключенном

зажигании включится блокировка двигателя, светодиод начнет мигать равномерными
длинными вспышками. Никакие другие зоны охраны в этом случае активированы не
будут, замки дверей не запираются.

Режим иммобилайзера также автоматически включится, если после выключения

зажигания все двери остаются закрытыми в течение 10 минут.

Для отключения иммобилайзера используется процедура 

DAPS

TM

.

Выберите с помощью программирования одну из приведенных в таблице комбина

ций кнопок пульта (заводская установка кнопка 1):

Чтобы отключить иммобилайзер, нажмите при включенном зажигании установлен

ную программированием комбинацию кнопок. Отключение пассивного иммобилайзера
система подтвердит двумя вспышками сигнальных фонарей.

Если по какимлибо причинам Вы не можете воспользоваться брелоком для отключе

ния иммобилайзера, введите PIN код, так же как при аварийном отключении.

Примечание: При одновременно включенных режимах пассивного иммобилайзера и

Anti Hijack, нажатием установленной комбинации кнопок на пульте управления или
вводом младшего разряда PIN кода оба режима одновременно отключатся. Для ввода

Кнопка 1

Кнопка 2

Кнопка 3

Кнопка М

1

2

3

4

5

 

6

 

7

 

8

 

9

1

2

10

1

2

11

1

2

12

2

1

13

1

2

14

1

2

15

2

1

16

2

1

17

1

2

18

2

1

19

2

1

20

2

1

Содержание EMS 1.7R

Страница 1: ...nd a pager system will warn you about any intrusion into your car Enhanced anti theft facilities are ensured by a powerful built in blocking relay and an additional universal output available to conne...

Страница 2: ...ng a command the transmitting indicator will be displayed on the LCD panel See the Command Summary for more details Button 1 Button 2 Button 3 Button S Button M Transceiver RF Range Conditions Pager R...

Страница 3: ...gered 24 Hour Clock Doors Locked Doors Unlocked Power Save Mode Engine Running Door Open Hood Open Trunk Open Low Battery Warning Ignition ON Transmitting a Command ValetMode PagerTest Button Lock Par...

Страница 4: ...to the current time display however the last value of the parking time will remain in the transceiver memory until the next arming You can check time of parking with pressing button S As soon as you a...

Страница 5: ...ton M and Button 3 together This will cause the alarm system to respond by sending the latest status information to the Transceiver so it can be immediately displayed on the LCD panel Power Save Mode...

Страница 6: ...isarmed Unlock Ignition ON Passive Immobiliser Disarmed Panic 3s Ignition OFF Car Finder Armed or Valet Mode with the ignition switched OFF Trunk Release 3s Anystatus Latch Output 2nd 1st 3 minute Tur...

Страница 7: ...le on the 2 Way Transceiver which armed the alarm system If another valid 2 way Transceiver is in range of the vehicle when the alarm system is triggered that Transceiver will not receive the pager si...

Страница 8: ...interior light in your car includes a delay when the door is closed turn this function on there will be no additional warning beeps on arming the alarm system with the interior light left switched on...

Страница 9: ...ming is set with programming Is flashing Melody 6 Reconnection of the Power Supply while Light Indicators are Melody 5 1time per 5 seconds Armed flashing Passive Immobiliser Trigger Period is Current...

Страница 10: ...of the first pressing NOTE 2 Stage Unlock is only available while disarming with ignition turned OFF 2 Stage Disarm To disarm the alarm system normally press the disarm button If the alarm system has...

Страница 11: ...ively NOTE If you use the Silent Arming Disarming modes the LCD transceiver will confirm the receipt of a response from the alarm system also without audible signals Arm with Engine Running Arming the...

Страница 12: ...ou have turned on the Anti Hi jack function then once you open a door with the ignition on firstly turn the Anti Hi Jack off see the Anti Hi Jack section for details and then fulfil the enter Arm with...

Страница 13: ...ith turbo timer but the engine will not be blocked until the ignition is switched off However if you set the Immobiliser Trigger Period with programming the alarm will be triggered in set time period...

Страница 14: ...second arming period Ignition Safety Door Lock Unlock This feature can be selected using programming 5 seconds after the ignition is turned on the doors will lock for passive safety and will automati...

Страница 15: ...itter as normal All features including auxiliary output panic mode car finder and arming of the alarm system will function normally If the ignition is switched on then the transmitter cannot be used t...

Страница 16: ...m and the passive immobiliser will disarm If option i is used then the alarm system will stop sounding and the alarm will disarm but the passive immobiliser will remain engaged You must still press th...

Страница 17: ...first time after reconnection of the car battery Anti Hi Jack NOTE The Hi jacking mode will only be available if you set a 2 digit Pin code The EMS 1 7R alarm system includes an Anti Hi Jacking Car J...

Страница 18: ...e siren will continue to sound and the immobiliser depending on the setting of the Installer s Function 1 5 will either remain disengaged until the ignition is switched off or operate in accordance wi...

Страница 19: ...er disarm command will be completely ignored until the Anti Hi jack has been exited Blocking in Trouble Simulation While in the Anti Hi jack This feature can be selected using programming The system i...

Страница 20: ...ctivated as soon as the alarm system is triggered and also as soon as a door is opened under armed condition when Entry Alarm Delay is turned on Self Diagnostics Functions Intrusion Warning If the doo...

Страница 21: ...leted Pager Test Once button 3 is pressed with the alarm system armed or armed with the engine running a Pager Test feature for current armed period will be included 5 minutes after you press button 3...

Страница 22: ...n the Latch Output with pressing button 2 immediately after button S the input will remain active until either disarming or pressing button 2 immediately after button S once again If you turn on the T...

Страница 23: ...ntil the indicator icon on the LCD screen is flashing two times to confirm the main unit code has been programmed to the transceiver otherwise the pager function will not work 8 To exit the Code Learn...

Страница 24: ...rated Car Jacking Mode ON OFF OFF ON OFF 2 7 Pre warn sensor zone triggered indication on the transceiver ON ON OFF 3 1 PIN Access 1 9 button 2 only or 1 Press 1 9 times to set Press 1 9 times to set...

Страница 25: ...MONGOOSE EMS 1 7R 25 Mongoose EMS 1 7R Mongoose EMS 1 7R Mongoose EMS 1 7R Anti Hi Jack KeeLoqTM Valet 8 Mongoose EMS 1 7R Mongoose EMS 1 7R EMS 1 7R 28 350 400 250 300 700 900 400 450 1500 800...

Страница 26: ...EMS 1 7R 26 3 5 Mongoose EMS 1 7R Mongoose EMS 1 7R MAwKTM Mongoose EMS 1 7R Mongoose EMS 1 7R Mongoose EMS 1 7R MONGOOSE EMS 1 7R 27 1 5 24 LR03 AAA 1 6 1 2 3 S M...

Отзывы: