43D0121

3

INSTALLER

Please leave these instructions with the owner.

OWNER

Please retain these instructions for future reference.

IMPORTANT

Read these instructions carefully before installing this vent-free fi rebox. 

W

ARNING

• Improper installation or use of the fi rebox can cause serious injury or death from 

fi re, burns, explosion or carbon monoxide poisoning.

• Do  not  allow  fans  to  blow  directly  into  the  fireplace.  Avoid  drafts  that  alter 

burner fl ame patterns.

• Do not use a blower insert, heat exchanger insert or other accessory, not approved 

for use with this fi rebox where applicable.

IMPORTANT SAFETY INFORMATION

   1. Due  to  high  temperatures,  the  fi rebox  should  be 

located  out  of  traffic  and  away  from  furniture 
and draperies.

   2. Children and adults should be alerted to the hazard 

of high surface temperature and should stay away 
to avoid burns or clothing ignition.

   3. Young  children  should  be  carefully  supervised 

when they are in the same room with the fi rebox.

   4. Do not place clothing or other fl ammable material 

near the fi replace when the fi rebox is in use.

5. Any safety screen or guard removed for servicing, 

must be replaced prior to operating a heater within 
the fi rebox. 

   6. Installation and repair should be done by a qualifi ed 

service person.

   7.  To prevent malfunction and/or sooting, an unvented 

gas  heater/firebox  should  be  cleaned  at  least 
annually  by  a  professional  service  person.  More 
frequent cleaning may be required due to excessive 
lint  from  carpeting,  etc.  It  is  imperative  that 
control compartments, burners and circulating air 
passageways be kept clean.

8.     The installation must conform with local codes or, in 

the absence of local codes, with the National Fuel Gas 
Code, ANSI Z223.l/NFPA 54. 

9.     This  unit  complies  with  Z21-91  Ventless  Firebox 

Enclosures  for  gas-fired  unvented  decorative  room 
heaters. 

10.   Do not install the fi rebox in a bathroom or bedroom.

11.   Avoid any drafts that alter burner fl ame patterns. Do not 

allow fans to blow directly into fi replace. Do not place 
a blower inside burn area of fi rebox. Ceiling fans may 
create  drafts  that  alter  burner  fl ame  patterns.  Sooting 
and improper burning will occur.

12.   

Caution:

  Candles,  incense,  oil  lamps,  etc.  produce 

combustion  byproducts  including  soot.  Vent-free 
appliances  will  not  fi lter  or  clean  soot  produced  by 
these types of products. In addition, the smoke and/or 
aromatics  (scents)  may  be  reburnt  in  the  vent-free 
appliance which can produce odors. It is recommended 
to minimize the use of candles, incense, etc. while the 
vent-free appliance is in operation. 

13.   Keep  room  area  clear  and  free  from  combustible 

materials,  gasoline  and  other  fl ammable  vapors  and 
liquids.

14.   During manufacturing, fabricating and shipping, various 

components  of  this  appliance  are  treated  with  certain 
oils, fi lms or bonding agents. These chemicals are not 
harmful but may produce annoying smoke and smells 
as  they  are  burned  off  during  the  initial  operation 
of  the  appliance;  possibly  causing  headaches  or  eye 
or  lung  irritation.  This  is  a  normal  and  temporary 
occurrence.

        The initial break-in operation should last 2-3 hours with 

the  burner  at  the  highest  setting.  Provide  maximum 
ventilation by opening windows or doors to allow odors 
to  dissipate. Any  odors  remaining  after  this  initial 
break-in period will be slight and will disappear with 
continued use.

 15.  Always  have  a  fireplace  screen  in  place  when  the 

appliance is in operation and, unless other provisions 
for combustion air are provided, the screen shall have an 
opening(s) for induction of combustion air. 

Содержание GLCF36

Страница 1: ... qualified installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Carefully review the instructions supplied with the decorative type unvented room heater for the minimum f...

Страница 2: ...LEARANCES and HEIGHT REQUIREMENTS 7 FIREPLACE FRAMING 9 FIREPLACE INSTALLATION 11 GAS LINE INSTALLATION 14 CANOPY and RADIANT PLATE INSTALLATION 15 SCREEN and OPTIONAL EQUIPMENT INSTALLATION 16 BLOWER INSTALLATION 17 GLASS REMOVAL FOR CLEANING 19 ILLUSTRATED PARTS LIST 20 WARRANTY BACK COVER CONTENTS ...

Страница 3: ...ith the National Fuel Gas Code ANSI Z223 l NFPA 54 9 This unit complies with Z21 91 Ventless Firebox Enclosures for gas fired unvented decorative room heaters 10 Do not install the firebox in a bathroom or bedroom 11 Avoid any drafts that alter burner flame patterns Do not allow fans to blow directly into fireplace Do not place a blower inside burn area of firebox Ceiling fans may create drafts th...

Страница 4: ...ion of the firebox system including but not limited to the firebox and accessories may void the warranty listings and approvals of this system and could result in an unsafe and potentially dangerous installation BEFORE YOU START CHECK YOUR PACKING LIST TO VERIFY THAT ALL LISTED PARTS HAVE BEEN RECEIVED ALSO INSPECT THE CONTENTS FOR SHIPPING DAMAGE AND IMMEDIATELY INFORM YOUR DEALER IF ANY DAMAGE I...

Страница 5: ...uire a different sequence 1 Position firebox prior to framing or into prepared framing 2 Field wire main power supply to circulating models with fan kit Electrical connections should only be performed by an experienced licensed certified tradesman 3 Plumb gas line Gas connections should only be performed by an experienced licensed certified tradesman 4 Install vent free gas log heater per the inst...

Страница 6: ...s for forced air furnaces air conditioners windows or doors Installation must provide adequate ventilation and combustion air DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR BATHROOM Location should be out of high traffic or windy or drafty areas DO NOT INSTALL WHERE CURTAINS FURNITURE CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 36 FROM FRONT OF HEATER Never obstruct the front opening of the ven...

Страница 7: ...e from the inside of the appliance to any combustible adjacent wall should not be less than 27 8 Refer to Figure 3 2 Ceiling Clearance The ceiling must be at least 42 from the top of the firebox opening Refer to Figure 3 3 Back Wall Clearance The appliance may be placed against a combustible back wall 4 Parallel Wall Clearance The clearance from the opening of the firebox to any wall that is paral...

Страница 8: ...installed If a combustible mantel is installed it must meet the clearance requirements detailed in Figure 5 6 Floor clearance This firebox hearth must be installed at least 61 2 above any combustible flooring material such as carpeting or asphalt tile which is closer than 14 to the base of the firebox Refer to Figure 6 Or The firebox hearth may be installed nearer to the floor if a minimum of 14 o...

Страница 9: ...ed on a flat wood plywood particle board or other hard surfaces Be sure firebox rests on a solid continuous floor or platform with appropriate framing for support so that no cold air can enter room from under the firebox Note Make sure a minimum 19 is between the studs A GPF36 GRCF36 GLCF36 Peninsula Corner A 19 minimum 21 minimum B 221 2 2 231 8 C 39 39 D 38 38 FIREPLACE FRAMING Figure 8 Top View...

Страница 10: ...is manual WARNING Figure 12 Top View of Framing Specifications for See Through Unit Model GSTF36 FIREPLACE FRAMING and INSTALLATION GSTF36 See Through A 19 minimum B 221 2 2 C 40 D 38 Figure 13 Framing Specifications for See Through Unit Model GSTF36 Two by Four Two by Two Gas Connection Two by Four Minimum Two by Two Minimum ...

Страница 11: ... 4 Attach nailing flanges to studs See Figure 14 5 Remove two baseplates from bottom of firebox See Figure 15 6 Anchor firebox to floor with four 3 16 x11 4 screws through holes located on the bottom of the firebox See Figure 14 7 Install canopy Refer to page 15 for canopy installation FIREPLACE INSTALLATION Figure 14 Location of Nailing Flanges and Floor Screws Nailing Flange 3 16 x 11 4 4 Screws...

Страница 12: ...es to 90 5 Level and plumb firebox by checking edges of firebox Shim if necessary 6 Attach nailing flanges to studs See Figure 17 7 Remove two baseplates from bottom of firebox See Figure 18 8 Anchor firebox to floor with four 3 16 x11 4 4 screws through holes located on the bottom of the firebox See Figure 17 9 Install canopy Refer to page 15 for canopy installation Figure 17 Location of Nailing ...

Страница 13: ...ox in its final position and frame later 4 Bend out four 4 nailing flanges to 90 5 Level and plumb firebox by checking edges of firebox Shim if necessary 6 Attach nailing flanges to studs See Figure 20 7 Remove two baseplates from bottom of firebox See Figure 21 8 Anchor firebox to floor with four 3 16 x11 4 screws through holes located on the bottom of the firebox See Figure 20 9 Install canopy R...

Страница 14: ...can be placed inside the firebox A plugged 1 8 NPT pressure taping point is recommended for service and may be incorporated to the valve assembly Bring a minimum 1 2 gas supply line through the knockout hole provided in the firebox A sediment trap may be upstream of the heater to prevent moisture and contaminants from passing through trap to the heater controls and burners Failure to do so could p...

Страница 15: ...are used with a fireplace facing Close fireplace screen panel before operating decorative type unvented room heater CANOPY AND RADIANT FACE PLATES INSTALLATION Figure 22 Canopy Installation Radiant Face Plate Figure 23 Installing Radiant Face Plates Radiant Face Plate Louvers INSTALLING RADIANT FACE PLATES 1 Remove the radiant face plates from the uprights on the top of the firebox Remove packing ...

Страница 16: ...EMS ONLY If you are installing the forced air kit Model BLO on the GSTF36 GPF36 GCRF36 or GCLF36 units see the installation instructions below INSTALLING PULL SCREEN FOR CORNER UNITS GRCF36 AND GLCF36 1 Slip the rings of the pull screen on the screen rod 2 Insert bent end of screen rod into hole inside the firebox as shown below 3 Align straight end of rod with hole on opposite side of firebox Sli...

Страница 17: ...e blower See Figure 30 page 18 WIRING TO JUNCTION BOX NOTE The wire must be run to the junction box before framing the firebox 1 Before installing blower wire the receptacle into an electrical circuit Use minimum 60 C wire in accordance to prevailing codes 2 The junction box is preinstalled at the factory Remove external junction box cover by removing the screw from either the left or right side o...

Страница 18: ... AND BTS 1 Removeaccesscoveronthefloorofthefirebox 2 Removeplasticplugfromaccesscover SeeFigure27 Removeplasticplugfromaccesscover SeeFigure27 Removeplasticplugfromaccesscover 3 Removetheknobfromthestemofthevariablespeedcontrol See Figure 27 4 Alignthestemofspeedcontroltolargestholeontheaccesscoverof the firebox Attach speed control with two 6 32 screws provided See Figure 27 Figure 27 Installing ...

Страница 19: ...Glass Figure 28 Removing Glass When Cleaning Glass Do not remove the glass when hot Allow glass to cool before removal Never use abrasive cleaning materials on glass Keep children and pets at safe distance away Never operate fireplace if glass is broken Replace any glass that is chipped cracked or broken Replacement glass frame assemblies MUST be supplied by the fireplace manufacturer Do not subst...

Страница 20: ...20 43D0121 ILLUSTRATED PARTS LIST ...

Страница 21: ...ver 20 6 43D0117 43D0117 7 Radiant Front 36 4 26D0576 26D0576 8 Radiant Front 20 2 43D0119 9 Weathered Brick 21 2 43D0086 9 Weathered Brick 21 1 43D0086 9 Weathered Brick 35 1 43D0085 10 Frame Glass Kit 1 43D0093K 11 Nailing Flange Kit 1 43D0032K 43D0032K 43D0032K ACCESSORIES 1 Brass Canopy 2 BRCU36 BRCU36 1 Brass Canopy 1 BRCU36 5 Brass Louver 36 2 L36BR L36BR 5 Brass Louver 36 1 L36BR 5 Chrome L...

Страница 22: ...22 43D0121 NOTES ...

Страница 23: ...43D0121 23 NOTES ...

Страница 24: ...n accordance with the installation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alteration negligence of others including the installation thereof by unqualified installers 2 the ...

Отзывы: