Monessen Hearth GLCF36 Скачать руководство пользователя страница 14

14

43D0121

W

ARNING

CA

UTION

Plumbing  connections  should  only  be  performed  by  a 

qualified,  licensed  plumber.  Main  gas  supply  must  be 

off  when  plumbing  gas  line  to  fi replace  or  performing 

service.

Connecting directly to an unregulated 

propane/LPG  tank  can  cause  an 

explosion.

Consult all local codes. All gas piping must be installed to comply with local codes, or in the absence of local codes, with 
the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA54.
Remove the access cover(s) on the front of the fi rebox for access to gas line installation. Knock out one of the four holes on 
the baseplate for gas line connection to the log set. 
The 

1

/

2

"  gas  line  may  enter  either  from  the  left  side  or  right  side  of  the  fi rebox  for  See-Through  Unit  (GSTF36).  Gas 

access holes are provided on both sides of the fi rebox.
For  the  Peninsula  Unit  (GPF36)  and  the  Corner  Units  (GRCF36  and  GLCF36),  the  1/2"  gas  line  must  enter  from 
the closed-side of the fi rebox. 
The gas supply line must have an ANSI approved manual shutoff valve, upstream of the appliance. Either a recessed valve 
with a key should be mounted to the wall or fl oor outside the fi rebox, or an on/off appliance-style valve with union can be 
placed inside the fi rebox. A plugged 1/8" NPT pressure taping point is recommended for service and may be incorporated to 
the valve assembly. Bring a minimum 1/2" gas supply line through the knockout hole provided in the fi rebox. 
A sediment trap may be upstream of the heater to prevent moisture and contaminants from passing through trap to the heater 
controls and burners. Failure to do so could prevent the heater from operating reliably. Consult applicable codes.

In addition to the regulator fi tted to the heater, an external regulator must be used on all propane/LPG heaters to reduce 
the supply tank pressure to 13" w.c. (maximum). Any copper tubing used to supply propane/LPG from the tank must be 
internally tinned. 

Note: When connecting propane/LPG vent-free room heaters, you must use pipe sealant 

resistant to propane/LPG.

Check gas type: The gas supply must be the same as stated on the heater’s rating plate. If the gas supply is different, 
DO NOT INSTALL THE HEATER. Contact your dealer for the correct model.

After completing connection, test all gas joints from the gas meter to the gas heater regulator for leaks. Using soap and 
water solution or a gas sniffer. DO NOT USE AN OPEN FLAME

GAS LINE INSTALLATION

W

ARNING

Do  not  connect  directly  to  natural 

gas 1/2 PSI or 2 PSI systems. Always 

make  sure  natural  gas  pressure  is 

regulated 10.5 w.c. (maximum before 

operating the unit). 

Содержание GLCF36

Страница 1: ... qualified installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Carefully review the instructions supplied with the decorative type unvented room heater for the minimum f...

Страница 2: ...LEARANCES and HEIGHT REQUIREMENTS 7 FIREPLACE FRAMING 9 FIREPLACE INSTALLATION 11 GAS LINE INSTALLATION 14 CANOPY and RADIANT PLATE INSTALLATION 15 SCREEN and OPTIONAL EQUIPMENT INSTALLATION 16 BLOWER INSTALLATION 17 GLASS REMOVAL FOR CLEANING 19 ILLUSTRATED PARTS LIST 20 WARRANTY BACK COVER CONTENTS ...

Страница 3: ...ith the National Fuel Gas Code ANSI Z223 l NFPA 54 9 This unit complies with Z21 91 Ventless Firebox Enclosures for gas fired unvented decorative room heaters 10 Do not install the firebox in a bathroom or bedroom 11 Avoid any drafts that alter burner flame patterns Do not allow fans to blow directly into fireplace Do not place a blower inside burn area of firebox Ceiling fans may create drafts th...

Страница 4: ...ion of the firebox system including but not limited to the firebox and accessories may void the warranty listings and approvals of this system and could result in an unsafe and potentially dangerous installation BEFORE YOU START CHECK YOUR PACKING LIST TO VERIFY THAT ALL LISTED PARTS HAVE BEEN RECEIVED ALSO INSPECT THE CONTENTS FOR SHIPPING DAMAGE AND IMMEDIATELY INFORM YOUR DEALER IF ANY DAMAGE I...

Страница 5: ...uire a different sequence 1 Position firebox prior to framing or into prepared framing 2 Field wire main power supply to circulating models with fan kit Electrical connections should only be performed by an experienced licensed certified tradesman 3 Plumb gas line Gas connections should only be performed by an experienced licensed certified tradesman 4 Install vent free gas log heater per the inst...

Страница 6: ...s for forced air furnaces air conditioners windows or doors Installation must provide adequate ventilation and combustion air DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR BATHROOM Location should be out of high traffic or windy or drafty areas DO NOT INSTALL WHERE CURTAINS FURNITURE CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 36 FROM FRONT OF HEATER Never obstruct the front opening of the ven...

Страница 7: ...e from the inside of the appliance to any combustible adjacent wall should not be less than 27 8 Refer to Figure 3 2 Ceiling Clearance The ceiling must be at least 42 from the top of the firebox opening Refer to Figure 3 3 Back Wall Clearance The appliance may be placed against a combustible back wall 4 Parallel Wall Clearance The clearance from the opening of the firebox to any wall that is paral...

Страница 8: ...installed If a combustible mantel is installed it must meet the clearance requirements detailed in Figure 5 6 Floor clearance This firebox hearth must be installed at least 61 2 above any combustible flooring material such as carpeting or asphalt tile which is closer than 14 to the base of the firebox Refer to Figure 6 Or The firebox hearth may be installed nearer to the floor if a minimum of 14 o...

Страница 9: ...ed on a flat wood plywood particle board or other hard surfaces Be sure firebox rests on a solid continuous floor or platform with appropriate framing for support so that no cold air can enter room from under the firebox Note Make sure a minimum 19 is between the studs A GPF36 GRCF36 GLCF36 Peninsula Corner A 19 minimum 21 minimum B 221 2 2 231 8 C 39 39 D 38 38 FIREPLACE FRAMING Figure 8 Top View...

Страница 10: ...is manual WARNING Figure 12 Top View of Framing Specifications for See Through Unit Model GSTF36 FIREPLACE FRAMING and INSTALLATION GSTF36 See Through A 19 minimum B 221 2 2 C 40 D 38 Figure 13 Framing Specifications for See Through Unit Model GSTF36 Two by Four Two by Two Gas Connection Two by Four Minimum Two by Two Minimum ...

Страница 11: ... 4 Attach nailing flanges to studs See Figure 14 5 Remove two baseplates from bottom of firebox See Figure 15 6 Anchor firebox to floor with four 3 16 x11 4 screws through holes located on the bottom of the firebox See Figure 14 7 Install canopy Refer to page 15 for canopy installation FIREPLACE INSTALLATION Figure 14 Location of Nailing Flanges and Floor Screws Nailing Flange 3 16 x 11 4 4 Screws...

Страница 12: ...es to 90 5 Level and plumb firebox by checking edges of firebox Shim if necessary 6 Attach nailing flanges to studs See Figure 17 7 Remove two baseplates from bottom of firebox See Figure 18 8 Anchor firebox to floor with four 3 16 x11 4 4 screws through holes located on the bottom of the firebox See Figure 17 9 Install canopy Refer to page 15 for canopy installation Figure 17 Location of Nailing ...

Страница 13: ...ox in its final position and frame later 4 Bend out four 4 nailing flanges to 90 5 Level and plumb firebox by checking edges of firebox Shim if necessary 6 Attach nailing flanges to studs See Figure 20 7 Remove two baseplates from bottom of firebox See Figure 21 8 Anchor firebox to floor with four 3 16 x11 4 screws through holes located on the bottom of the firebox See Figure 20 9 Install canopy R...

Страница 14: ...can be placed inside the firebox A plugged 1 8 NPT pressure taping point is recommended for service and may be incorporated to the valve assembly Bring a minimum 1 2 gas supply line through the knockout hole provided in the firebox A sediment trap may be upstream of the heater to prevent moisture and contaminants from passing through trap to the heater controls and burners Failure to do so could p...

Страница 15: ...are used with a fireplace facing Close fireplace screen panel before operating decorative type unvented room heater CANOPY AND RADIANT FACE PLATES INSTALLATION Figure 22 Canopy Installation Radiant Face Plate Figure 23 Installing Radiant Face Plates Radiant Face Plate Louvers INSTALLING RADIANT FACE PLATES 1 Remove the radiant face plates from the uprights on the top of the firebox Remove packing ...

Страница 16: ...EMS ONLY If you are installing the forced air kit Model BLO on the GSTF36 GPF36 GCRF36 or GCLF36 units see the installation instructions below INSTALLING PULL SCREEN FOR CORNER UNITS GRCF36 AND GLCF36 1 Slip the rings of the pull screen on the screen rod 2 Insert bent end of screen rod into hole inside the firebox as shown below 3 Align straight end of rod with hole on opposite side of firebox Sli...

Страница 17: ...e blower See Figure 30 page 18 WIRING TO JUNCTION BOX NOTE The wire must be run to the junction box before framing the firebox 1 Before installing blower wire the receptacle into an electrical circuit Use minimum 60 C wire in accordance to prevailing codes 2 The junction box is preinstalled at the factory Remove external junction box cover by removing the screw from either the left or right side o...

Страница 18: ... AND BTS 1 Removeaccesscoveronthefloorofthefirebox 2 Removeplasticplugfromaccesscover SeeFigure27 Removeplasticplugfromaccesscover SeeFigure27 Removeplasticplugfromaccesscover 3 Removetheknobfromthestemofthevariablespeedcontrol See Figure 27 4 Alignthestemofspeedcontroltolargestholeontheaccesscoverof the firebox Attach speed control with two 6 32 screws provided See Figure 27 Figure 27 Installing ...

Страница 19: ...Glass Figure 28 Removing Glass When Cleaning Glass Do not remove the glass when hot Allow glass to cool before removal Never use abrasive cleaning materials on glass Keep children and pets at safe distance away Never operate fireplace if glass is broken Replace any glass that is chipped cracked or broken Replacement glass frame assemblies MUST be supplied by the fireplace manufacturer Do not subst...

Страница 20: ...20 43D0121 ILLUSTRATED PARTS LIST ...

Страница 21: ...ver 20 6 43D0117 43D0117 7 Radiant Front 36 4 26D0576 26D0576 8 Radiant Front 20 2 43D0119 9 Weathered Brick 21 2 43D0086 9 Weathered Brick 21 1 43D0086 9 Weathered Brick 35 1 43D0085 10 Frame Glass Kit 1 43D0093K 11 Nailing Flange Kit 1 43D0032K 43D0032K 43D0032K ACCESSORIES 1 Brass Canopy 2 BRCU36 BRCU36 1 Brass Canopy 1 BRCU36 5 Brass Louver 36 2 L36BR L36BR 5 Brass Louver 36 1 L36BR 5 Chrome L...

Страница 22: ...22 43D0121 NOTES ...

Страница 23: ...43D0121 23 NOTES ...

Страница 24: ...n accordance with the installation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alteration negligence of others including the installation thereof by unqualified installers 2 the ...

Отзывы: