3.2
Input / Output Connecons
The Nova-Pro has input and output jacks on
the side that can be used for external
triggering
or
synchronizaon
(daisy
-
chaining two or more strobes). These jacks
accept 1/8” [3.5 mm] phone plugs (input-
stereo, output-mono). The input jack
provides a source of power (5Vdc @ 75mA) to power an external
sensor and will accept a signal from 3 to 12 volts. The output is TTL
compable (3V) and provides a pulse synchronized to the internal
generator (flash rate) or external input signal. Connecon details
are shown in Figures 3 and 4 below.
Out (
)
In (
)
Figure 3 Input Connector Detail (Stereo plug)
Figure 4 Output Connector Detail (Mono plug)
6
Common (GND)
Pulse Output
from Nova-Pro
Pulse Output
from Nova-Pro
Common (GND)
Common (GND)
+5V Out to
Sensor
Signal Input
Signal Input
+5V Out to Sensor
Common (GND)