Connections and their functions are as follows:
+Vout
Positive +5 or +10 V dc (user selectable) to provide power
to optical, laser, infrared or amplified magnetic sensors.
Maximum load is 75 mA dc.
SIG IN
Input signal from signal sources or speed sensor. Accepts
TTL pulses or ac signals, unipolar and bipolar, from
±
3 to
±
12
Volts. Connect the signal wire from 3-wire sensors or the
positive side of two wire sources to this terminal. Typical input
impedance is 10 Kohms.
COM
Common or Negative connection for both signal and power
from most sensors/sources.
Refer to the User Settings section for input option settings. Typical
connection for Monarch standard sensors is shown below: