background image

F2A1X

Frequency to Analog Converter Module

15 Columbia Drive  •  Amherst, NH 03031  USA

Phone: (603) 883-3390  •  Fax: (603) 886-3300

E-mail: [email protected]

Website: www.monarchinstrument.com

Instruction Manual

Содержание F2A1X

Страница 1: ...X Frequency to Analog Converter Module 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarchinstrument com Instruction Man...

Страница 2: ...conditions that exceed the environmental specifications stated 3 Be sure the power supplied to this instrument matches the specification indicated on the rear panel of the instrument 4 Be sure all po...

Страница 3: ...NTS 1 0 OVERVIEW 1 2 0 INSTALLATION 1 2 1 Power 2 2 2 Analog Out 2 2 2 1 Current Output Option 3 2 2 2 Voltage Output Option 3 2 3 Sensor Input 3 3 0 USER PROGRAMMABLE HARDWARE SETTINGS 5 3 1 Sensor P...

Страница 4: ...put signal The device is powered from 12 to 24 V dc and consumes less than 100 mA and can be operated freestanding or can be mounted to a panel using the fixing wings on either end of the device The F...

Страница 5: ...uring that the positive wire goes to the terminal and the common or negative wire goes to the terminal 2 2 Analog Out The Analog Out terminals are the source for the voltage or current output as order...

Страница 6: ...o the terminal marked and the other side of the load to the terminal marked 2 2 2 Voltage Output Option The voltage output is 0 to 5 V dc Connections for voltage out are to the terminals marked ANALOG...

Страница 7: ...pts TTL pulses or ac signals unipolar and bipolar from 3 to 12 Volts Connect the signal wire from 3 wire sensors or the positive side of two wire sources to this terminal Typical input impedance is 10...

Страница 8: ...ings are done by moving jumpers on the circuit board inside the housing To access these jumpers REMOVE ALL WIRING FROM THE UNIT Then remove the two screws on the bottom of the unit and remove the base...

Страница 9: ...upling for the external signal Can be set to DC default for most digital input sources or AC for sine wave and bidirectional sources or sensors that provide negative going pulses Once the jumpers have...

Страница 10: ...and full scale settings as specified when ordered or programmable using USB Programming Cable and PM Remote Software Resolution 76 microvolts or 30 5 micro amps Power Supply 12 to 24 V dc 5 150 mA ma...

Страница 11: ...r to tinned leads ROS HT W 25 Remote Optical High Temp PN 6180 058 25 Remote optical sensor for high temperature applications with visible incandescent white light source P5 11 Proximity PN 6180 013 T...

Страница 12: ...ogram the unit The software also allows remote monitoring of the RPM using a graphic display or an Excel spreadsheet Software available for download at monarchinstrument com T 5 Reflective Tape PN 618...

Страница 13: ...Firmware revision n C1 Shows all settings C2 Shows all settings with CR after each parameter D0 Sends current display value once D1 Sends display data continuously at up to display update rate D2 Stop...

Страница 14: ...imal places DAC1 FSCAL Shows Analog Out Full Scale DAC1 FSCAL xxx xx Sets the Reading value that the Analog output will output Full Scale 5 V or 20 mA depends on TYPE DAC1 0SCAL Shows Analog Out Zero...

Страница 15: ...12 This page intentionally left blank...

Страница 16: ...ssional s Choice Track It Data Loggers Panel Tachometers DataChart Paperless Recorders Speed Sensors Portable Tachometers Portable Strobes Frequency Converters Fixed Mounted Strobes 1071 4145 112 0522...

Отзывы: