2.3 USB Programming Cable and Software
The 3.5 mm connection “hole” in the center bottom of the rear panel is
for the optional USB Programming Cable (PN 6180-031), which comes
with Windows™ compatible
PM (Panel Meter) Remote Software
. The
cable and software combination allows the user to configure: operation
mode, analog output scaling, decimal places, display update rate and
pulses per input. The user can also view real-time data in digital format
and/or through Excel®. Software instructions are included with the
software downloaded from
3.0 SENSOR CONNECTIONS
A speed sensor (not included) is connected to the terminals under the
section labeled INPUT on the rear panel. Refer to Figures 2 and 3.
Connections and their functions are as follows:
+VA
Po12 V dc to provide power to optical, laser, infrared or
amplified magnetic sensors. Maximum load is 75 mA dc.
Optionally 5 or 24 V dc supply may be ordered.
PX+
Po12 V dc supply for use with two-wire proximity sensors.
Maximum load for proper operation with two-wire sensors is
25 mA.
SIG
Positive input signal from the speed sensor. Accepts TTL pulses or
ac signals, unipolar and bipolar, from 1.5 V ac to 50 V ac. (Contact
the factory for increased sensitivity.) Connect the signal wire from
three-wire sensors or the positive side of two-wire magnetic
sensors to this terminal. Typical input impedance is 10 kilo ohms.
COM
Common or Negative connection for both signal and power from
most sensors.
Refer to Figure 3 (next page) for connection of Monarch standard sensors.
The connections are typical for these types of sensors.