HarshIO 600
•
59
•
IP67 MDR for EtherNET/IP
Description
Values
Owned
Set to 1 when at least one EO connection is present
Configured
Set to 1
Minor Recoverable fault
-
Set when UB detect an under voltage
Major Recoverable fault
-
Set when Rotary position changes
-
Set when Configuration Control changes (attr3, 0xF5)
-
Set when Interface Configuration changes (attr5, 0xF5)
-
Set when IP address is lost.
E
x
te
n
d
e
d
S
ta
tu
s
At least one faulted I/O connection
Managed by stack.
No IO connection established
Managed by stack
Major Fault
Same as “Major Recoverable fault”
At least one I/O connection in Run mode
Managed by stack
At least one I/O connection established, all in Idle mode
Managed by stack
Instance Services
Id
Service
Param. Options
01h
Get_Attributes_All
05h
Reset
0: supported
1: supported
2: supported
0Eh
Get_Attribute_Single