01/08 AWB2190-1430GB
Copier function with
DEX-KEY-10
137
Copy and Read function example
Speed control unit RA-SP (A) with connected and configured
keypad DEX-KEY-10.
The parameters of RA-SP (A) are configured for the connected
drive unit (application, series machine).
The table below describes the steps required to copy the
parameters of RA-SP (A) to three further, identical RA-SP units (B,
C and D), with the same application (drive unit):
Step
Pushbutton
Description
Data exchange
1
The parameters saved in RA-SP (A) are read into the keypad.
(A)
A
2
Switch off the power supply of RA-SP (A) and disconnect the
keypad’s connection cable.
3
Connect the keypad’s connection cable to RA-SP (B) and switch on
the power supply.
4
1)
The parameters saved to the keypad are copied to RA-SP (B).
This takes about 10 seconds.
A
(B)
5
Switch off the power supply of RA-SP (B) and disconnect the
keypad’s connection cable.
6
Repeat steps 3 to 5 for RA-SP units (C) and (D).
A
(C, D)
1) Note on step 4
If individual parameters are changed after you have pressed the COPY key (for example the acceleration time), you can carry out step 4a here without
changing the keypad’s saved data.
4a
After issuing the COPY command, you can use the keypad to
change the copied parameters of RA-SP (B). The changed data is
automatically saved to RA-SP (B).
The keypad’s memory content is not affected by this operation.
A
(B)
To also apply the parameters changed in step 4a to RA-SP units (C) and (D), save them to the
keypad.
4b
The parameters saved in RA-SP (B) are read into the keypad.
This overwrites the parameters saved in step 1 so that the keypad
now contains the parameters changed in step 4a.
(B)
A
READ
RMT
ALARM
FWD
REV
PRG
POWER
RUN
READ
COPY
MNT
PRG
ENTER
COPY
RMT
ALARM
FWD
REV
PRG
POWER
RUN
READ
COPY
MNT
PRG
ENTER
COPY
RMT
ALARM
FWD
REV
PRG
POWER
RUN
READ
COPY
MNT
PRG
ENTER
RMT
RMT
ALARM
FWD
REV
PRG
POWER
RUN
READ
COPY
MNT
PRG
ENTER
READ
RMT
ALARM
FWD
REV
PRG
POWER
RUN
READ
COPY
MNT
PRG
ENTER
Содержание Rapid Link
Страница 10: ...01 08 AWB2190 1430GB 6 ...
Страница 40: ...01 08 AWB2190 1430GB 36 ...
Страница 48: ...01 08 AWB2190 1430GB 44 ...
Страница 70: ...01 08 AWB2190 1430GB 66 ...
Страница 145: ...01 08 AWB2190 1430GB Parameterization with DrivesSoft 141 Figure 134 Example acceleration time ...