background image

   

Installation Guide    Lighting Fixture

Installation Guide

Lighting Fixture

Input voltage

Input current
Input wattage

29.0W / 30.3W

95 mm × 95 mm

3 47/64” × 3 47/64”

Ceiling cut out

MMP-080F/CWF.CMF/20B/Z1/2

MUSEUM DOWNLIGHT FOUNDATION

120V / 277V

0.26A / 0.13A

Ceiling

Weight

thickness

The fixture is for indoor use only in general conditions.This fixture can only be installed on a horizontal ceiling.

Can not be used following conditions (Causes of falling, electrocution and fire)

●Ambient temperature under 0℃ and over 35℃

●High humidity
●Outside
●On the floor
●Vibrated or shocked areas
●Areas get direct sunlight

●Inclined, uneven surface

●Ceiling which canʼt hold the fixture weight
●On the wall
●Places affected by wind or air-conditioner machine
●Near fire
●Dusty areas, corrosive gas outbreaks areas

Before

installation

For electric

wiring

At lighting

fixture 

installation

Warning

Warning

Warning

Warning :  Failure to install the fixture properly could result in personal injury.

Failure to install the fixture properly could result in property damage.

: Prohibited

Read and understand these instructions before installing fixture.

Retain these instructions for maintainance reference.

This fixture is intended for installtion in accordance with the National Electrical Code and local regulations. To assure full compliance with

local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at

fuse box before proceeding.

: Strict observance

Caution : 

Caution

Caution

To install the fixture safely《 Read carefully and follow all the instructions in the guide 》

Please follow the fixturesʼ indication or specification for the distance of irradiated area.

 (Causes of change in shape, change in color of irradiated objects)

Please contact if you are not able to judge whether installation 

environment is suitable to the places or not.

Only qualified person may work on electric wiring and equipment. (Cause of accidents)

Be sure power supply voltage is within ±6%  mentioned in rating plate or the guide. (Causes of short life of lamps・electrification・fire)

Be sure all the wires and codes are not damaged. (Causes of falling・damage)

Please follow the fixturesʼ instruction or this guide to install the fixture and lamp. (Causes of falling・electrification・fire)

Switch off the power when installing the lamp. (Causes of electrification)

Do not touch the fixture when switch is on or just turn off the switch because of high temperature.

Do not put or cover the fixture by any cloths, papers, or insulators.(Causes of not lighting・fire)

Do not place any metallic or flammable objects. (Cause of electrification・fire・broken fixture)

Make sure to install all the parts of fixtures besides installation and mounting parts will not touch with any

objects both inside and outside of ceiling such as lighting track, etc. (Causes of falling・electrification・fire) 

Do not dismount or remodel fixtures. (Cause of electrification・fire・falling・broken fixtures)

Do not operate with wet hands.
If you smell smoke, see smoke, or find anything unusual, please turn the switch off and ask construction

companies to repair. (Cause of electrification・fire)

Make sure the construction will not affect any fire prevention systems such as sprinkler by heat from the fixture. 

(Causes for improper operation)

Use alternating current.  Please follow rating plate of fixtures for power supply frequency. 

(Cause of electrification・fire) (50Hz ・60 Hz common use for ballasts and incandescent lamp fixtures)

LED DRIVER (BUILT-IN)

OT40W/PRG1400C/UNV/DIM

(OSRAM)

Please use the dimmer 

adapted to the led driver

39

/6

4"

4 9/64"

8 5/16"

1 1

1/6

4"

10 3/64"

13

/3

2"

2 13/16" 71.5mm

255mm

111

.9m

m

142

.5m

m

211mm

29.

6m

m

23

/6

4"

-6

3/

64

"

9-2

5m

m

3m

m

1/

8"

105mm

2.183 lbs

990 g

9〜25mm

23/64”

~63/64”

Содержание MMP-080F

Страница 1: ...ects Please contact if you are not able to judge whether installation environment is suitable to the places or not Only qualified person may work on electric wiring and equipment Cause of accidents Be sure power supply voltage is within 6 mentioned inratingplate or the guide Causes of short life of lamps electrification fire Be sure all the wires and codes are not damaged Causes of falling damage Ple...

Страница 2: ...s and connections back in wiring box and replace cover Make sure the supply wire connec tions remain separate and are locat ed in the larger junction box comp artment a b Slide the metal fittings from upper side Use a screw driver and tighten the metal fittings On step 2 please fix the metal fitting firmly with your fingers If not it may cause falling of fixtures a b Make sure to tighten the metal fitting...

Страница 3: ...lage et l équipement électriques Cause d accidents Assurez vousquelatensiond alimentationestde 6 decellementionnéedanslaplaquesignalétiqueouleguide Causes de courte durée des lampes électrification feu Assurez vous que tous les câbles et les codes ne sont pas endommagés Causes de chute dégât Veuillez suivre les instructions de l appareil ou ce guide pour installer l appareil et la lampe Causes de c...

Страница 4: ...lliques sont serrées fermement avec un tournevis couple 1 0 2 0 Nm Si elles sont serrées de façon trop lâche l appareil risque de tomber couvercle de la boîte 4 1 21 Kitahama Chuo ku Osaka 532 0011 Japan Tel 81 6 7167 2474 OSAKA VIOLET GRIS LIMITÉ 0 10 V FILS DE COMMANDE JUSQU À VARIATEUR 0 10 V Pour variation 0 10 V Faire les deux connexions aux fils violet et gris et les placer de nouveau dans le...

Отзывы: