In order to avoid a hazard due to inadvertent resetting of the Earth
Leakage Circuit Breaker (ELCB), this appliance must not be supplied
through an external switching device, such as timer or connected to
a circuit that is regularly switched “On” and “Off” by the utility.
This water heater is equipped with adjustable flow capacity safety
valve. For the safety use, please do not change the location of the
water heater installation and do not block its water outlet.
MODENA will not be liable for any responsibility regarding to any
improper installation and incorrect operation of this appliance.
This water heater can be used for other purposes (e.g. washing
hands, dishes or foods, and so on)
When the water heater is used by children, elderly, or person(s) with
special needs for their mental and physical capabilities, the heat-
checking of water temperature by using hand from time to time is
necessary.
Children should be supervised to ensure that they do not play with
this appliance.
EI 2D B
PART 2: NAME OF PARTS
Main Control
Board
Thermal
Cut-out
Tank
Front Cover
Water Outlet
Marker (Red)
Power Knob
Water
Inlet
Ring Circlip
Stainless-steel
Water Inlet
Marker (Blue)
Flow Switch
Silicon Control
Display Board
Display
Button
Terminal Block
Water
Outlet