reset The Camera To Factory Settings
3.7.4
All settings of the MOBOTIX camera can be reset permanently to the factory default settings.
This makes sense if you have, for example, obtained a camera without any information
or you would like to reset all settings after testing the camera. In order to perform this
procedure, you need to have access to the Administration Menu of the camera (admins
group). Open
Admin Menu > Reset
to reset the camera to factory defaults.
Note
Note: All defined users are deleted and the admin password is reset to the factory
default when you reset the camera using
Admin Menu > Reset
. If you want to maintain
existing users, use the method described in Section 3.2.6
Starting the Camera with the
Factory IP Address.
Activate Event Control And Motion Detection
3.7.5
In its default configuration, the camera's event control and video motion detection features
are not enabled. In order to activate event-controlled recording, open
Setup Menu >
General Event Settings
and activate the Arming switch. Another method is to click on the
Arm & Record
soft key in the browser's user interface. The camera displays the video
motion detection window in the live image (dotted frame in the center) and the camera
automatically stores images as soon as the video motion window detects movements.
Deactivate Text And Logo Options
3.7.6
As the camera arming is deactivated in its default configuration (see preceding section),
the MOBOTIX camera displays only the text
WWW.MOBOTIX.COM
, the time stamp and
the MOBOTIX logo at the top of the image. Once the camera arming has been activated,
the text at the bottom of the live image (event, action, messaging, and recording symbols)
will also appear.
You can deactivate the status bar at the bottom of the live image and the text bar in the
top left-hand corner by setting Text Display in the
Setup Menu > Text & Display Settings
dialog box to
Off
. Setting Text Display to
Date and Time
will only display the time stamp
in the live image.
To hide the logo in the live image, open
Admin Menu > Logo Profiles
and set Logo
Display to
Deactivated
.
Deactivating The Daily Automatic Camera reboot
3.7.7
By factory default, the MOBOTIX camera automatically reboots every morning at 3:36 a.m.
The reason for this is that in some rare cases, external influences (for example, radiation
at high altitudes) can lead to camera malfunctions. The automatic reboot will refresh the
camera's memory and will ensure proper operation without requiring any interaction on
the part of the user. If desired, you can deactivate the automatic reboot of the camera in
the
Admin Menu > Time Tasks
dialog.
The configuration can
also be reset partially
If the dotted
rectangle in the live
image is visible, the
camera is armed
Text and logos can be