13
4. USE OF THE INPUTS AND OUTPUT
4.1 CONNECT A SENSOR TO THE INPUT
It is possible to connect two external sensors
to the inputs. As a standard reaction after a
triggered input, the Mobeye CML2275 sends
an SMS text message to the preset numbers
and calls these numbers.
Insert the 2 wires of an external sensor
through the hole of the enclosure to the
inside part and next in the two connectors of
input 1 (press on the green pins for
connecting the wires). It does not matter which wire is connected to which connector.
When using a second input, connect this to input 2.
As default the inputs are programmed as Normally Open (NO) contacts. This means
the inputs are triggered if the input is closed for at least 1 second. In case the contact
is Normally Closed (NC), please refer to paragraph 6.8. If you require the sensor to be
activated for a shorter or longer period before triggering an alarm, please refer to 6.8.
4.2 CONNECT A DEVICE TO THE OUTPUT
The Mobeye CML2275 has an open collector
output, which switches after receiving a
correct SMS or after an alarm. The output
can switch permanently, or just switch for a
pulse time after which the output
automatically switches back (see 6.15).
The maximum load of the output is 200mA.