![Mobeye ThermoGuard TwinLog CML2275 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/mobeye/thermoguard-twinlog-cml2275/thermoguard-twinlog-cml2275_user-manual_1814844010.webp)
9
2.4 ENTER THE PROGRAM MODE
In order to program the unit, the GSM module needs to be open and connected to the
network. Using external power, the unit is always in program mode.
A battery-operated unit switches to the program mode after inserting the batteries.
First the GSM module establishes network connection. During this time the LED
flashes green and red. Within 10-30 seconds the connection is established and the
status LED starts flashing 1 sec. on/1 sec. off (or stays on continuously in case the first
telephone number has been configured).
The Mobeye CML2275 returns to the program mode by pressing the button for 5
seconds, until the LED starts flashing red/green. Once it has GSM connection it will be
flashing again (or stays on continuously).
As long as the unit is in program mode, the status green LED is on (or flashing 1 sec.
on/1 sec. off if the module has no configuration). During the first 3 minutes, the GSM
module remains active, ready to receive SMS commands. After 3 minutes a time-out
occurs and the GSM module switches off in order to save the batteries. The unit
returns to the low power operational mode.
2.5 PROGRAM AT LEAST ONE TELEPHONE NUMBER
The Mobeye CML2275 is able to send messages up to 5 telephone numbers. The first
telephone number (TEL1) belongs to the administrator. Technical messages (such as
battery low
) are sent to the administrator only. Without the administrators
’ phone
number, the Mobeye CML2275 cannot function.
When the CML2275 is in initial (factory) status and the batteries are inserted (so the
LED is flashing), the administrators
’ number is programmed by calling the telephone
number of the Mobeye CML2275 using the
administrators’ phone. The unit will
recognize this number and store it as administrator (TEL1). The administrator will
receive a confirmation SMS text message including the security code. This code is
needed to program the other settings in the unit.
NB: For this way of programming the number recognition in the administra
tor’s phone
must be ‘on’. To program or change the administrators’ number by SMS command,
please refer to 5.2.